The models FACT 20, FACT 40 and FACT 60, are intended for
indoor use only and must be kept away from moisture and
dust.
The models FACT 20LG, FACT 40LG and FACT 60LG, have a pro-
tection degree IP55, so they can be placed outside.
Keep the indicated distances between the heater and the wall/ceil-
•
ing (fig. 1-2-3).
Install the heater in such a way that the lamps stay horizontally.
•
A safety distance of not less than 1 m should always be left in front
•
of the heater.
The appliance must not be located neither directly below, nor in
•
front of a socket-outlet.
Do not use the heater directly near a bathtub, a shower, a swim-
•
ming pool.
Ensure that the power cable cannot come into contact with the re-
•
flector of the appliance and does not intrude into the area of light flux.
Ensure that there is no possibility of inflammable material, combus-
•
tible material or curtains coming into contact with the Heater, or lie
near the heater.
Wall mounting using the braket (provided)
Make sure that the wall where you plan to mount the appli-
ance is solid, and free of electrical cables or water pipes in-
side.
This heater is intended for permanent installation. Be sure
that the heater is not facing the ceiling or inflammable sub-
FACT 20-
Model
FACT 20LG
220-240V ~
Power supply
50–60Hz
Total power
2000 W
Current
Cable H05RN-F
3 x 1.5 mm² 3 x 2.5 mm² 5 x 1.5 mm²
(min.section)
(*) Cable minimum section - per 5 m length.
FACT 40-
FACT 40LG
220-240V ~
50–60Hz
4000 W
9 A
18 A
9
FACT 60-
FACT 60LG
380-415V ~
50–60Hz
3P+N
3 x 2000 W
3 x 9 A