3. Protection
12
The bath is provided with equipotential connection
located on the motor base plate, must be connected to the bathroom's equipotential installation. The
connecting wire may have a section from anywhere between 2,5 mm and 6 mm .
The electrical wiring of the house must include a differential circuit breaker (page 12,13) of at least 30 mA,
according to the current regulations of the geographical area where it is installed, and a thermomagnetic
circuit breaker suited to the power consumption of each bath model. (see consumption on the technical
specifications). The latter will be provided with an omnipolar disconnection and with an opening distance
of at least 3 mm. Both circuit breakers must be located outside the protection volumes of the bathroom.