Anleitung Ölradiator SPK7
it with the wing nut (3). Repeat the above on the
last space between the ribs.
4. Technical data:
MR 510
Rated voltage:
230 V ~ 50 Hz
Output:
1000 W (500 W/1000 W)
Thermostat control:
Infinitely adjustable
Heating ribs:
Protection class:
Mains lead:
3 x 1 mm
MR 715
Rated voltage:
230 V ~ 50 Hz
Output:
1500 W (600 W/900 W/1500 W)
Thermostat control:
Infinitely adjustable
Heating ribs:
Protection class:
Mains lead:
3 x 1 mm
MR 920
Rated voltage:
230 V ~ 50 Hz
Output:
2000 W (800 W/1200 W/2000 W)
Thermostat control:
Infinitely adjustable
Heating ribs:
Protection class:
Mains lead:
3 x 1 mm
5. Proper use
The appliance is designed only for private use, not
for commercial heating purposes.
6. Starting up
Important! Before using the appliance for the first
time, check that the voltage supply is the same as
the voltage details set out on the data plate.
Read safety instructions listed under section 1.
6.1 Function switch (Fig. 4):
MR 510:
Low output – activate switch (1) or switch (2)
Maximum output – activate switches (1+2)
04.04.2006
14:42 Uhr
MR 715/MR 920:
Low output – activate switch (1)
Medium output – activate switch (2)
Maximum output – activate switches (1+2)
The possible output levels are listed in the technical
data in point 4.
6.2 Thermostat control/Room thermostat
(Fig. 4 / Item 3):
Switch on the required output using the two function
5
switches. Turn the control to "MAX" until the required
I
room temperature has been reached. Then turn
2
x 1,25 m
down the control until you hear a clear click. The
thermostat control will switch the radiator on and off
automatically to maintain the room temperature at an
almost constant level. However, this presupposes
that the radiator has a sufficient output to cover the
heating requirements for the room.
7
I
2
x 1,25 m
7. Storage
If the radiator is not used for a lengthy period of time,
the mains lead must be stored in full in the
compartment provided for it. The radiator has to be
stored in a dry place, covered if possible.
9
I
2
x 1,25 m
8. Maintenance and cleaning
Maintenance and repair work may only be carried
out by an authorized electrical servicing contractor
or the customer service responsible for your
country.
Check the mains lead at regular intervals for signs
of defects or damage. A damaged mains lead may
only be replaced by an electrician or the customer
service responsible for your country in compliance
with the relevant regulations.
Important: Disconnect the mains lead before
cleaning – danger of electric shock.
Use a damp cloth to clean the casing.
The ribs are filled with a special oil. Repairs that
necessitate the oil seal to be opened may only be
carried out by the customer service responsible for
your country. If oil leaks from the appliance, return
it to the customer service responsible for your
country for examination.
Seite 7
GB
7