Descargar Imprimir esta página

IMER COMBI 250/1000 VA Manual De Uso página 11

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

The power lines must be laid to prevent any possible damage.
Ensure that the electrical connection is protected against the risk of wa-
ter penetration in connectors. Use exclusively connectors and couplings
equipped with water spray protection.
Never use inadequate or makeshift electrical lines or cables without
earthing; if in doubt consult a specialised technician.
Repairs to the electrical circuit must be performed exclusively by specia-
lised personnel. Disconnect the machine from the power supply before
performing maintenance or repairs.
Note that this machine has been designed to ensure optimal performan-
ce and maximum safety: however the operator must also guarantee this
level of safety by paying special attention to the machine throughout all
work phases.
The Combi 250/1000 VA has been constructed taking into account cur-
rent harmonised European safety standards.
According to machine directive 98/37/EEC all safety devices have been
installed with the aim of safeguarding the operator.
and protections that prevent access to moving or dangerous parts.
envisaged to protect the operator (maintenance engineers, technicians
and others) from possible accidents cause by electrical discharge or
moving mechanical parts.
way is strictly prohibited.
IMER INTERNATIONAL S.p.A.
COMBI 250/1000 VA - COMBI 250/1500 VA
Remove the machine packing.
The machine can already be used, leaving the legs folded, resting its
Frame assembly:
1. remove the machine and tank from the folded frame.
2. remove the safety pins from the frame and open the legs.
3. put the safety pins back in the holes provided locking the legs in the
open position.
4. reposition the machine and tank on the frame.
The Combi 250/1000 VA sawing machine weighs 57 Kg (the 250/1500
Va 80 kg) and can be moved using the side handles on the tank (ref.I,
distances, before moving the machine, close the frame reversing the
sequence of the operations described in point 8.1.
-
Every time the machine is moved, make sure the head is locked tighte-
-
-
The additional table can be installed to the left or right of the machine, or
on both sides at the same time.
front legs.
-
into the grooves, which hold it perfectly vertical.
Now install the additional table; it is supplied with the side mounts alre-
ady assembled. Fit the mounts into the provided cavities in the side
-
panels of the machine, making sure they are fully inserted. Now lower
the additional table until it is properly supported. Level the additional
table with that of the machine itself; to do this, move the strut to the left
-
-
-
The power supply line must be equipped with current overload pro-
tection (e.g. thermal-magnetic cutout) and protection against indirect
contact (e.g. residual current circuit breaker).
The electrical power distribution board at the construction site must
conform to the requirements of EN 60439-4.
The size of the power cable conductors must be based on operating
current and length of the power line to prevent excessive voltage drops
(table 4).
Combi 250/1000 VA
- 250/1500 Va
Check the integrity of the insulation and protective conductor of the elec-
trical supply.
Connect the machine plug to the electrical power supply and tighten the
mechanical retainer ring with IP67 protection rating.
The machine is now ready for operation.
11
Table 4
Model
Type of motor
1.5
230 V
0 ÷ 22
7.8 A
110 V
0 ÷ 11
15.4 A
GB
-
-
-
-
-
Cable (mm²)
2.5
4.0
23 ÷ 36
37 ÷ 58
12 ÷ 18
19 ÷ 30

Publicidad

loading