Risk Of Fire; Technical Data; General Data - Tronic KH 3901 Instrucciones De Uso

Transformador
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Risk of fire!

• Do not use the device near hot surfaces.
• Do not locate the device in places exposed to
direct sunlight, Otherwise, it may overheat and
become irreparably damaged. Do not operate
the device in a vehicle that is standing out in the sun.
• Do not leave the device unattended when in use.
• Do not cover the fan's ventilation slots when the
device is switched on.
• Do not place any open sources of fire, like candles,
on the device.
• Due to high crossover resistances heating of the
plug in connector can result when using the ca-
bles with a 12 V vehicle plug.
Notice regarding disconnection from
the power supply
• This device's on/off switch does not completely
disconnect the device from the vehicle's power
and/or the battery. When the vehicle plug is
connected power is still supplied to the device.
To completely disconnect the device from the
vehicle power supply the 12 V vehicle plug must
be removed from the 12 V vehicle receptacle.
Risk of personal injury!
• Keep children away from the connecting cable
and the device. Children frequently underestimate
the dangers of electrical appliances.
• Do not operate the device if it has fallen or is
damaged. Have the device checked and repaired
if necessary by qualified technicians.

Technical data

DC Input
Voltage :
Maximum voltage:
Maximum power
consumption:
Underload alarm:
Underload shutoff:
Overload shutoff:
AC Output
Voltage :
Output power:
Continuous load:
Peak load:
Efficiency:
Output wave form:
Overload protection:
Temperature Switch-off: 65°C
Fuses
Power inverter:
Power failure protection switch
Power failure
shut off:

General data

Measurements (without vehicle plug)
(L x B x H):
Weight :
Operating temperature:
Operational humidity:
(relative humidity - no condensation)
Subject to technical changes.
- 19 -
12V
15,5 V
20 A
at 10,6 ± 0,3 V
at 10 ± 0,3 V
at 16 ± 0,5 V
220-240 V ~ 50 Hz
0,65 A
150 W (> 4 h)/
170 W (30 min)
300 W (0,1 s)
approx. 85 %
modified sine
200 W (+/- 5%)
(at 50W +/- 5% Loading)
20 A automotive flat fuse
>3 mA
185 x 73 x 58 mm
470 g approx.
5°...40°C
0 - 80 %

Publicidad