Aspen Xtra AX3007/1 Manual De Instrucciones página 15

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 73
When the water level of the bottom tray reaches predetermined level,
the digital display area shows «P1» and the WATER FULL indicator light
illuminates. Carefully move the unit to a drain location, remove the
bottom drain plug and let the water drain away. Reinstall the bottom
drain plug and restart the machine until the P1 symbol disappears.
If the error repeats, call for service.
Note: Be sure to reinstall the bottom drain plug before using the unit.
Cleaning Air Filter
If the air filter is covered by dust, the cooling capability will be
decreased. Please clean the air filter every two weeks, dependant
on use.
• Turn off the power supply
• Pull out the filter cover and remove the filter from cover
• Vacuum off the surface of the filter and then if necessary wash air
filter in warm soapy water. Do not put air filter in the dishwasher or
use any chemical cleaners. And dry filter completely before replacing.
• Attach the air filter to the filter cover using the attachment hooks
on the inner surface of the cover. Put the filter cover back to it's place.
Duct mount instruction flexible
1a. Connect the exhaust air outlet hose by screwing into the round hose
adaptor. Clip the hose and adaptor onto the air outlet of the unit.
2b. Connect the appropriate adaptor onto the opposite end of the air
outlet hose.
3c. Fit the adaptor sub-assembly to a nearby window.
Note:
• The duct can be compressed to 270mm minimum and extended to
1500mm maximum. It is better to keep the duct length to a minimum.
• The exhaust air must always be vented to outside.
• Stretching or bending the duct excessively will affect the cooling efficiency.
Bottom tray
drain outlet
15

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Xtra ax3008/1

Tabla de contenido