SHuTdOWn
. Remove all load by turning off electrical appliances and
unplugging electric cords.
2. Allow engine to run at idle speed (2500 and 3000), or at no
load condition (3000-MH0, 4000, 5000) to cool for two (2)
minutes.
NOTE: Failure to allow the engine to cool for two (2)
minutes may result in damage to the generator.
3. Turn engine key or ignition switch off.
4. Close fuel valve on unit or engine.
COnTROlS

CONTROL PANEL:

The generators are equipped with the following items:
GEN-2500-0MS0, GEN-3000-0MH0, GEN-3000-1MH0:
-
Circuit Breaker
-
One 25 volt, 20 Amp, GFCI protected receptacles.
GEN-4000-0MS0, GEN-4000-0MH0, GEN-5000-0MS0:
-
Full Power Switch
-
Circuit Breakers
-
Two 25 volt, 20 Amp, Duplex (2 outlets), GFCI protected
receptacles.
-
One 25 volt, 30 Amp, Locking Type Receptacle.
-
One 25/250 volt, 20 Amp, Locking Type Receptacle.
NOTE: The 125 Volt, 30 Amp locking receptacles ARE NOT
GROUND FAULT PROTECTED. If ground fault protection
on these receptacles is necessary or desired, external
protection devices must be used. Refer to the section on
"Ground Fault Interrupter" for more information.
WARnInG: neVeR exCeed THe RATInG Of A
ReCePTACle. These receptacles are
protected against overloads by resetting
magnetic type circuit breakers. If a circuit
breaker trips, the cause should be determined
and corrected prior to continuing use.
Operator's Manual
Operating the Generator
2