PROBLEM
Converter does
not turn on.
10. SPECIFICATIONS
Maximum continuous output ................................................................. 750 Watts
Surge capacity (0.1 second) ............................................................... 1500 Watts
No load current draw ...................................................................................<0.5A
Input voltage range .................................................................. 10.5V – 15.5V DC
Output voltage range ...................................................................... 120V±5% AC
Optimum efficiency ........................................................................................ 85%
11. REPLACEMENT PARTS
12V accessory plug with cables ...................................................... 3899003535Z
Battery cable with clamps (red and black) ...................................... 3899003534Z
12. BEFORE RETURNING FOR REPAIRS
For REPAIR OR RETURN, contact Customer Service at 1-800-621-5485. DO NOT
SHIP UNIT until you receive a RETURN MERCHANDISE AUTHORIZATION (RMA)
number from Customer Service at Schumacher Electric Corporation.
POSSIBLE CAUSE
Poor contact at terminals
Fuse has blown.
For information about troubleshooting,
contact customer service for assistance:
services@schumacherelectric.com
www.batterychargers.com
or call 1-800-621-5485
Check for poor connection to
battery or power supply. Make sure
connection points are clean. Rock
clamps back and forth for a better
connection.
A blown fuse is usually caused by
reverse polarity or a short circuit
within the converter. Contact
a qualified service technician
to replace the fuse(s) with the
appropriate replacement(s).
• 10 •
REASON/SOLUTION