- English -
Storage/Winterization
The unit is protected from frost:
The unit can be operated as long as the water temperature does not go below 39 °F (+4 °C).
The unit is not protected from frost:
Take the unit out of operation at water temperatures below 46 °F (+8 °C) or, at the latest, when freezing temperatures
are to be expected.
● Drain the unit as far as possible, clean thoroughly and check for damage.
● Empty all hoses, pipes and connections as far as possible.
Wear parts
The following components are wear parts and are excluded from the warranty: UVC lamp, quartz glass and O ring for
quartz glass, and the Cleaning rotor
Disposal
Do not dispose of this unit with domestic waste! Disable the unit beforehand by cutting off the cables. Further
information about the recycling of this product can be obtained from your local municipal authority. Dispose of the
UVC lamp by using the return system provided for this purpose.
Troubleshooting
Issue
Cause
Water remains
The water is extremely soiled.
cloudy (green
water).
Insufficient delivery rate of the pump
The quartz glass is soiled
The quartz glass is scratched.
The cleaning rotor is not turning.
− Check the inspection window:
An alternating light/dark blue glow
indicates that the cleaning rotor is
rotating.
The UVC lamp capacity is exhausted.
Incorrect bypass setting
No or
Inlet nozzle clogged
insufficient
Outlets clogged
water flow at
the outlets
UVC lamp is
Power plug not connected
not lit.
UVC lamp defective
Connection defective
The unit has switched off due to
overheating (safety switch-off).
Questions, problems, missing parts?
Before returning to your retailer, call us at 1-866-627-3435, 8 a.m.-6 p.m., EST, Monday-Friday, or email
us at customercare@oase-livingwater.com. Or visit our website at www.oase-livingwater.com
Solution
− Remove algae and leaves from the pond.
− Change the water.
Check the installation.
Clean the quartz glass.
− Replace the quartz glass (See Cleaning the quartz glass)
− If the profile is worn, replace the cleaning rotor (See
Cleaning the quartz glass)
− Clean the cleaning rotor and quartz glass (See Cleaning
the quartz glass)
− If the delivery rate of the pump is < 2.642 gal/h (10.000 l/h),
use an inlet nozzle for driving the cleaning rotor.
− If the profile is worn, replace the cleaning rotor (See
Cleaning the quartz glass)
Replace the UVC lamp after 8000 operating hours.
Correct the setting, observe the pump capacity.
Clean the inlet nozzle.
Clean the casing (See Cleaning and maintenance)
Connect the power plug
Replace the UVC lamp
Check the electrical connection.
Allow it to cool down; the unit will switch back on
automatically.
11