3. SHUTDOWN AT THE END OF THE WORK
SHORT DURATION SHUTDOWN
- Decrease the material pressure of air regulator (D) until reading 0 bar / 0 psi on gauge (E).
- Trigger the gun to depressurize the system.
- Unscrew the gun air regulator (F) or disconnect the gun air inlet.
- Remove the gun air cap and the nozzle (only in case of an Airmix® gun) from the spray gun and
soak it into solvent.
LONG DURATION SHUTDOWN
- Decrease the material pressure of air regulator (D) so that the pump runs slowly.
- Unscrew the gun air regulator (F) or disconnect the gun air inlet.
- Remove the gun air cap and the nozzle (only in case of an Airmix® gun) from the spray gun and
soak it into solvent.
- Remove the suction rod from the material container and immerse it in a solvent-filled container. Take
all the appropriate precautions in the presence of flammable solvents.
- Point the gun towards the container and trigger the gun. When the solvent flows out, point the gun
towards the recovery container.
- When the solvent flows out clean, release the gun trigger.
Nota : If the pump is an Intensive™ one, release the spray gun trigger when the pump
- Fully unscrew the air regulator (D) and shut off the compressed air valve (valve H).
- Trigger the spray gun to decompress the hoses. Therefore, the pump and the hose remain filled with
solvent at the atmospheric pressure.
4. SAFETY DEVICE
Guards (air motor cover, coupling shields, housings ...) have been designed for
The manufacturer will not be held responsible for bodily injury or failure and / or
damage to property due to removal or partial removal of the guards
AIRMIX pump : A relief-valve (setting : 6.5 bar / 94 psi) is fitted on the pump air motor - thus protecting
this one from an overpressure which could damage it.
KREMLIN REXSON
piston is in a low position. To prevent from damaging the seals when starting
once again the pump, the piston must be immersed into solvent.
safe use of the equipment.
- 4 -
N° : 578.051.120-UK-1510