INSTALLATION
The cooker hood must be installed centrally over a cooking appliance. The minimum distance
between the cooking surface and the metal grease filters on the underside of the hood must be
at least 650mm.
To install the hood proceed as follows:
1) Drill six 8mm diameter holes at X1-X2-J and insert the plastic rawl plugs supplied as illus-
trated in fig. 2 ensuring the brackets are fitted as shown in the blow up.
2) Secure the two brackets C to the wall inserting two of the screws supplied through the two
holes on line X1-X2 as illustrated in fig. 2.
3) Slide the canopy down the wall to locate the key hole over the washer then secure the can-
opy to the wall by inserting two of the screws supplied through the two outer holes in the
rim of the canopy J1 and J2 as illustrated in fig. 3.
4) EXTRACTION OR RECIRCULATION INSTALLATION:
• EXTRACTION (DUCTED)
When installing the ducted version, connect the hood to the chimney using either a flexible or
rigid pipe ø 150 or 120 mm, the choice of which is left to the installer.
•
To install a ø 120 mm air exhaust connection, insert the reducer flange 9 on the hood body
outlet.
•
Fix the pipe in position using sufficient pipe clamps (not supplied).
•
Remove any activated charcoal filters.
• RECIRCULATION (FILTERED)
•
When the hood is fitted in the recirculation mode the Air Outlet Connection H should be
fitted as illustrated in fig. 6.
•
Fit the (optional) charcoal filters by repeating the following operation on each side of the
motor housing. Place the two key hole slots in the filter L and turn the filter clockwise to
lock the filter in position as illustrated in fig. 7.
WARNING: Failure to clean the metal grease filters and replace the charcoal filters regu-
larly represents a possible fire hazard.
Fitting The Chimney
5) FITTING THE UPPER CHIMNEY
Fit the upper chimney A (fig. 8) to the brackets C (fig. 2/ fig. 8) using the four 2.9mm self
tapping screws provided. The distance between the fixing holes X1 and X2 is determined
by the height of the upper chimney H.
6) FITTING THE LOWER CHIMNEY
To fit the lower chimney B, apply slight force to the two edges to increase the width of the
aperture, then insert chimney B into the hood (fig. 9).
EN
8
8