Technical Data

Power supply
AC voltage 230 V ~, 50 Hz, single-phase
12 V input
DC voltage 12 V from the battery
Output voltage
DC voltage 12 V
Output
PS 35 Automatic 35 VA (W), continuous operation
PS 50 Automatic 50 VA (W), continuous operation
Ambient temperature
-20 °C to +30 °C
Configuration
In accordance with the VDE provisions and the device
safety law
Dimensions / weight
Casing Plastic, ventilated
Length 135 mm
Width 125 mm
Height 75 mm
Weight PS 35 (50) Automatic 1.5 (1.7) kg
The right to effect technical modifications is reserved!
10
Troubleshooting
Error
Rectification
The 12 V output
Check that the device plug is securely
is not supplied
inserted into the mains socket.
with power
when in mains
Press the push button of the 230 V circuit
supply mode.
breaker.
Ensure that the device is well ventilated.
Ensure that the ventilation slits on the
device are not blocked.
The device may become too warm when
overloaded in mains supply mode. The
power drawn must not exceed the output
power of the device.
The 12 V output
Test the 10 A fuse on the battery and
is not supplied
replace if necessary.
with power
when in battery
Check that the flat plugs and the cables
mode.
on the 12 V input are connected tightly.
Check the battery voltage and charge the
battery if necessary.
Short-circuit on
Disconnect the cable on the 12 V output
the 12 V output
and remedy the short-circuit.
(consumer).
Test the 10 A fuse on the battery in
battery mode and replace if necessary.
Press the push button of the 230 V circuit
breaker in mains supply mode.
If these measures do not solve the problem, please
contact the Truma Service Centre.