Anl. HWA 2000 5spr.
GB
5. Technical data
Royal
Mains supply:
Power rating:
Delivery rate max.
Delivery height max.
Delivery pressure max..
Suction height max.
Delivery and intake connection:
Water temperature max.
Sound pressure level:
Sound power level:
Art.-No.:
6. Electrical connections
Connect the power cable to a 230 V 50 Hz
earthed, 10 amp fuse minimum.
The appliance is switched on and off using the
integrated ON/OFF switch. The pilot lamp inside
the switch lights up when the motor is switched
on.
The motor is protected against overloading or
blocking by an integrated thermostat. In the event
of overheating, the thermostat switches off the
pump automatically. The pump will start up again
automatically after it has cooled down.
7. Intake line
Screw an intake hose (min. 3/4" plastic hose with
spiral reinforcement) either directly or with a
threaded nipple to the pump's intake connection
(1" IG) (see Fig. 1+2).
The intake hose used should have an intake
valve. If the intake valve cannot be used, a check
valve should be installed in the intake line.
The intake hose should rise from the water pick-
up point to the pump. Always avoid laying the
intake line higher than the pump. Air bubbles in
the intake line delay and hinder suction.
8
07.11.2001 14:59 Uhr
HWA 2000
230V ~ 50 Hz
900 W
3600 l/h
42 m
4,2 bar
8 m
1" IG
35°C
66 dB(A)
76,6 dB(A)
41.765.00
Seite 8
HWA 2000 INOX
230V ~ 50 Hz
900 W
3600 l/h
42 m
4,2 bar
8 m
1" IG
35°C
66 dB(A)
76,6 dB(A)
41.765.50
The intake and pressure lines must be attached in
such a way that they do not place the pump under
any mechanical strain.
The intake valve should be so far immersed in the
water that the pump cannot run dry even if the
water level falls.
If the intake line is not air-tight, the intake of air
will hinder the intake of water.
Avoid drawing in foreign bodies (sand etc.).
If necessary, install a prefilter for this purpose.
Pressure line
1
connection
Intake line
connection
HWA 2000
2 0 0 0
H W A