OPERATING INSTRUCTIONS
Before each use, the accessories should be carefully checked so as to make sure that there
are no dust, deposits, lumps or liquid substances inside the connection tubes, the anti-spill
vessel, the bottle and their lids. Accurately clean or disinfect these parts strictly following the
instructions for "CLEANING AND DISINFECTION".
1. Connect the antibacterial filter (13) and/or the air inlet (3) of the appliance to the "A" outlet (OUT)
(11) of the anti-spill vessel by means of the short tube (12). By means of the long tube (10) connect
the "B" inlet (IN) (7) of the anti-spill vessel (6) to the breast shield (9) screwed on the bottle.
2. Plug the power cord into a power socket corresponding to the voltage of the appliance.
3. Place the appliance on a level surface making sure not to obstruct the air slots.
4. Operate the appliance by turning the switch on (1).
5. The desired level of vacuum (bar) can be set by using the vacuum regulation knob (4). A higher
vacuum level is obtained by turning the knob in the (+) direction; a lower vacuum level is obtained
by turning the knob in the (-) direction. These values can be read on the vacuum gauge (2).
6. Place the breast shield (9) over your breast. Place your finger on the hole C of the breast shield
(9) and start operation. By means of pressing discontinuously with your finger, pulsed suction can
be achieved.
7. When the operation is finished, turn off the appliance. Before restarting the appliance make sure
that it has cooled down to room temperature.
8. Unplug the appliance; empty and clean the feeding bottle and the connection tubes.

CLEANING AND DISINFECTION

• Disconnect the long tube (10) from both the bottle and the anti-spill vessel. Unscrew the breast
shield; empty and clean the bottle. Disconnect the short tube (12) from both the anti-spill vessel
and the appliance (or the antibacterial filter where provided). In order to clean the accessories
immediately after each use, it is sufficient to rinse the disassembled parts under running water.
To remove any impurities use the bottle brush (19) and the teat brush (18).
As required by Regulation (EU) 321/11 of the European Commission, all components of this Kit, made
for contact with milk, are made of materials that DO NOT contain BISPHENOL A.
Disinfection of these components must only be performed with common chloro-oxidising disinfectants
available on the market (Milton, Amuchina, etc.) in accordance with the directions indicated on the
packaging of the disinfectant itself.
Do not disinfect or subject components to: boiling, steaming or sources of heat in general.
• The disposable antibacterial filter (where provided) must be replaced within 24 hours of first use.
• Never wash the appliance under running water or soak in water; wipe it only with a damp cloth
using mild detergents. Do not use abrasive cleaners.
• Reassemble the bottle, the anti-spill vessel and the connection tubes by following the
"INSTRUCTIONS FOR USE".
ACCESSORIES - TECHNICAL FEATURES
- 125 ml anti-spill vessel
- Ø 4 X 6 mm connection tube, length 160 mm
- Ø 4 X 6 mm connection tube, length 1000 mm
- 250 ml feeding bottle
- Breast shield
- Ring for bottle teat
- Ring cap
- Teat brush
Microbial contamination
The accessories, bottle, anti-spill vessel and connection tubes are for single person use only, to
prevent cross infections.
- Bottle cap
- Teat
- Ring lid