Thank you for your faith in our products!
We have produced these Instructions for use and Maintenance so as to enable you to use your central
vacuum cleaning system in the best way possible. These instructions are meant for the central vacuum
cleaner models V3, V4 and V6. Nameplate markings (Type): TE-1650-..-.., TE-1950-..-..
Please read the instructions carefully before using the system and follow all instructions in this manual. The
detailed installation instructions for the wall inlets and parts of the piping can be found in the installation
manual for the Allaway central vacuum cleaning system. You can ensure the operation, efficiency, and
long service life of your central vacuum cleaning system by following all instructions and by only using
original Allaway parts and supplies. Keep the stickers from the product packaging to facilitate further
purchases and expansion of the system.
Keep the machine out of reach of small children. The machine is not a toy. The machine should not be
used by persons with reduced physical, sensory, or mental abilities. Monitor and instruct older children
and persons with insufficient experience or skills in the use of the machine.
GENERAL GUIDELINES
These central vacuum cleaners are only designed for domestic use and should only be used by one
n
person at a time and only for cleaning normal dust and rubbish.
Prior to starting up the unit for the first time, please check that the dust canister is empty and that
n
the filter is in place.
If the central unit is used for vacuuming anything other than normal dust, a suitable Alla-
n
way pre-separator must be used.
The wall inlets are equipped with catchers that stop large particles from entering the pipe system,
n
and longitudinal objects are caught in the steep elbow couplings located behind the inlets.
Only one wall inlet can be open at a time when the system is operational, and the covers of all other
n
inlets must be closed. Keeping more than one inlet open at a time weakens the suction power of
the system and increases the risk of blockages.
1 INSTALLATION
1.1 POSITIONING OF THE CENTRAL UNIT
l For detailed instructions for installation, please refer to the separate instructions for installing Allaway
central vacuum cleaning systems, which are supplied as standard with pipe kits PPK-44 and PPC-44 and
can also be ordered separately. The instructions can also be found on our website at www.allaway.fi.
Please follow local regulations for installations.
n
The room in which the central unit is installed must be sufficiently spacious and dust-free to allow
n
for the cooling air required for the motor.
The temperature of the room in which the central unit is located must not drop below +5 ° C or
n
rise above +35 °C, even while the unit is operational. The heat produced by the motor of the central
unit is released into the room. It is therefore important to ensure that air can circulate freely around
the unit and that the unit is not covered with textiles, for example, and that the room is adequately
18
ventilated.