cardboard; it could be necessary to cover even the rear side of the PV module. We saw that if you connect to
the controller SPC07-IP some kind of PV modules the controller is not able to detect the night. If you are in
such conditions, please contact
Configurations:
In all configurations the following processes are guaranteed:
The regulation of the battery's charge voltage, compensated in temperature, by external or internal NTC.
Load deactivation at reaching Low-Battery threshold (a red ligthning), selectable to 11V (dip switch 6 ON) or 12 V
(dip switch 6 OFF).
System inhibition at reaching Overtemperature threshold (two red ligthnings of the LED).
It is possible to exit from a low battery condition only during daylight.
Switchs
Description
Standard battery charger*:
Loads A and B always on.
Complete "light sensor" with complementary outputs*:
Load A ON only during day.
Load B ON only during night.
Remote load *:
The load is controlled by the contact on Sens input; closed to gnd => load A ON, opened => load A
OFF. Load B always ON.
Light sensor with IR *:
Load A ON during night ("light sensor" by the panel) for 5 minutes every time the IR sensor notices
the passage of a person.
Load B ON only during night.
LoadA
LoadB
Lamp ON for all night long*:
Load activated during night, from sunset (detected by the PV module) until sunset.
LOAD B manages the lamp energy saving
LoadA
LoadB
Lamp to max Brightness
Lamp in energy save, half brightness
Lamp off
Light sensor with timer 6h *:
Load ON during night, from sunset (revealed by the module) for 6 hours.
Load B manages the lamp energy saving (see * temporal diagram)
Light sensor with timer 8h *:
1
ON
Load ON during night, from sunset (revealed by the module) for 8 hours.
Load B manages the lamp energy saving (see * temporal diagram)
1
Light sensor with timer 8h delay 1h *8
ON
Load ON during night, one hour after sunset (revealed by the module) for 3 hours.
Load B manages the lamp energy saving (see * temporal diagram)
Light sensor with timer 10h *:
Load ON during night, from sunset (revealed by the module) for 10 hours.
Load B manages the lamp energy saving (see * temporal diagram)
*(see temporal diagram)
LoadA
LoadB
Lamp to max Brightness
Lamp in energy save, half brightness
Lamp off
1
Road flashing indicator - alternated 50% *:
Lightning loads at 50% ( 0,5s A on and B off, 0,5s A off and B on). From twilight ("light sensor" by the
ON
panel) and for the whole period of darkness, the power supplied to loads is reduced to a half.
User manual
Western CO. Support
5 min
5 min
timer
2 min
2 min
timer
2 min
2 min
SPC07-IP
Center.
3
Scheme of load connection
BLU
VERDE/GREEN
IR Sensor
ROSSO/RED
PX01
BLU
VERDE/GREEN
IR Sensor
PX01
ROSSO/RED
DIMMER
LAMP
GND
12V
12 LED
You can exclude the Energy saving not connecting the dimmer
signal. In this way the lamp will remain ON for all the time of
the timer at its maximum luminosity.
+LoadA
-LoadA
+LoadB
-LoadB
DIMMER
LAMP
GND
12 LED
12V
Semaforo/
Semaphore
+LoadA
-LoadA
+LoadB
-LoadB
SPC07-IP
EN
Gnd
Sens
+LoadA
-LoadA
12V Aux Max 100mA
+LoadB
-LoadB
SPC07-IP
Gnd
Sens
+LoadA
-LoadA
12V Aux Max 100mA
+LoadB
-LoadB
SPC07-IP
Gnd
Sens
SPC07-IP