3.5. Pre-start checks
Ensure the voltage and frequency of the
supply corresponds to the values indicated
on the electrical data label.
Ensure that the pump shaft is rotating freely.
The hydromassage assembly should be equipped
with a system to prevent the pump from starting up
if a minimum water level is not present. The pump
should wait until the water reaches that level.
Check all joints and connections for leaks.
THIS PUMP MUST NEVER BE DRY RUN.
4. STARTING
Ensure all valves in the pipework are open.
Apply voltage to the motor and suitably adjust the
jets to obtain the desired flow.
Viewings from the fan ensure that the rotation of the
motor is clockwise.
Ensure that the absorbed current is the same or
lower than the maximum shown on the name plate.
Adjust the thermal relay if is necessary.
If the pump fails to operate refer to the possible
faults, causes and solutions list for assistance.
5. MAINTENANCE
Under normal conditions these pumps require no
special or planned maintenance.
Clean the pump with a damp cloth without using
harsh products.
If the pump is not to be operated for a long
period it is recommended to remove it from
the installation, drain down and store in a dry,
well ventilated place.
ATTENTION: In the event of faults or
damage occurring to the pump, repairs
should only be carried out by an authorised
service agent.
The
Official
Technical
www.espa.com.
6. DISPOSING OF THE PRODUCT
When the pump is eventually disposed of, please
note that it contains no toxic or polluting material.
All main components are material identified to allow
selective disposal.
This product or parts of it must be disposed of in an
environmentally
sound
collection service. If this is not possible, contact the
nearest ESPA service workshop.
Services
list
is
in
way,
use
the
waste
7.
PLATE SHOWING CHARACTERISTICS
DESCRIPTION
1
Item reference
2
Voltage + frequency + item specifications
3
Flow
4
Pressure
5
Nominal voltage, no. stages, alternate current symbol and frequency
6
Capacitor (Single-phase model)
7
EC mark
8
Humidity protection level
9
Maximum pressure
10
Year and week of manufacture + Pump serial no.
11
Thermal protection incorporated indicator
12
Max. liquid temperature
13
Electric pump unit absorbed power(P1)
14
Designated motor insulation
15
Continuous operation symbol
16
Maximum nominal intensity at nominal voltage
17
Name and address of vendor responsible for the product
11
EN