INSTRUCTION MANUAL (Translation from the original Spanish)
Damage prevention and safety instructions
A
Warning! Observe limitations of use.
B
The name plate voltage must be the same as the
mains voltage.
C
Connect the pump to the mains via an omnipolar
switch with at least a 3mm opening between contacts.
D
Install a high-sensitivity differential switch (0.03A)
as extra protection against lethal electric shocks.
E
Connect the pump to the ground.
F
Use pump only within performance limits indicated
on the name plate.
G
Remember to prime pump.
H
Check for motor self-ventilation.
Contents
Safety precautions .................................................. 9

1. General considerations ...................................... 9

2. Technical features ........................................... 10
3. Installation ....................................................... 10
3.1. Emplacement ......................................... 10
3.2. Hydraulic installation .............................. 11
3.3. Connection to mains power .................... 12
3.4. Signals cables connection ...................... 12
4. Operating modes ............................................. 12
5. Configuration ................................................... 12
6. Start-up ............................................................ 12
6.2. Start-up ................................................... 12
7. Maintenance .................................................... 12
8. Commom malfunctions .................................... 13
9. List of main components .................................. 42
Safety precautions
This symbol
following words "Danger" or "Warning" indicates the
risk level deriving from failure to observe the
prescribed safety precautions:
DANGER
risk
of
electric
shock
DANGER
WARNING
together with one of the
Warns that failure to
observe the precautions
involves a risk of electric
shock.
Warns that failure to
observe the precautions
involves a risk of damage
to persons and/or things.
Warns that failure to
observe the precautions
involves
the
risk
of
damaging
the
pump
and/or the facility
(See figure
I This apparatus may be used by children 8 years
or older and persons with reduced physical,
sensory
or
mental
experience and knowledge, if they are supervised
or receive adequate training on the safe use of the
apparatus and understand the dangers.
Children should not be allowed to play with the
apparatus.
Children should not perform the ordinary cleaning
and maintenance tasks without supervision.
J Be
careful
with
environments.
K Caution! Look out for accidental leaks.
Do not expose pump to bad weather.
L Caution! Avoid icing.
Cut out power supply before servicing pump.
1. GENERAL CONSIDERATIONS
DANGER: Before proceeding to install the
product, read these instructions carefully.
WARNING: Guard with care this manual for
consultations after the first installation
Pressure sets are used with water supply systems to
increase and maintain pressure. These systems are
installed primarily in residential buildings, hospitals,
hotels and industrial buildings.
CPE sets are conventional sets with constant speed
pumps, controlled by ECD controller. CKE pressure
sets, with regulated speed pumps, are designed to
deliver water at a constant pressure, controlled by a
ESD controller.
Using a pressure transducer, the ESD/ECD receives
a signal that is proportional to the installation's
pressure. Depending on the scheduled start-up or
shutdown pressure, the set's pumps start up and
shut down in a staggered and alternating fashion.
CKE
There are 2 types of CKE sets: with auxiliary pumps
"on-off" and with variable speed pumps.
In booster sets with variable speed pumps, all the
electric pump motors are equipped with ESD
inverter, and each inverter communicates with the
others. The start-up of each motor and the rotating
speed is determined by the water consumption at
any given time. The operation mode is alternated, for
each activation of the booster set, the order of start
pumps is random. In booster sets with auxiliary 'on-
off' pumps, the main pump is equipped with a ESD
inverter and the auxiliary pumps are equipped with
ELV controler for starting and stopping the pumps.
The entire set is controlled by the ESD. The
operation mode is alternated, for each activation of
the booster set, the order of start pumps is random.
In both types, the pre-selected pressure is constant.
The same set can be powered at 50Hz or 60Hz.
9
EN
5)
capacities,
or
lacking
hazardous
liquids
and

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Cpe serieCke 2Cke 1Cke 4Cke 3

Tabla de contenido