Positioning the setting sleeve
4.4.
With the F-Senso entry force measuring device, it is possible to consider tolerances
between spindle and tool.
Measuring is to be implemented in the represented position of the setting sleeve (see
circled area in right-hand display), if no wear is present on tool receptacle, spindle
shaft and clamping set. By adjusting the setting sleeve, wear can be considered in
case of the measurement.
• First adjust the setting sleeve to required position.
• One latching of the setting sleeve corresponds to an axial displacement of
0,1 mm.
• The setting sleeve must have engaged exactly after every adjustment.
• Rotating the setting sleeve in "+" direction means an extension of the tension
element on the adapter; rotating in " - " direction means a shortening.
(Expressed differently, a displacement of the flat surface with respect to the
clamping slant of the adapter).
Heinrich-Röhm-Str. 50, 89567 Sontheim/Brenz., GERMANY, Tel. (49)7325/16-0
Operation