POSSIBLE FAULTS AND RELATED PERMITTED REMEDIES
G
FAULT
B
Reduction of performance. Frequent start-up.
Low pressure values.
The compressor stops and restarts automatically
after a few minutes.
After a few attempts to restart, the compressor.
The compressor does not stop and the safety
valve is tripped.
Any other type of operation must be carried out by authorized Service Centers, requesting original parts. Tampering with the machine may impair
its safety and in any case make the warranty null and void.
Warranty and repair.
In the event of defective goods or requirements for spare parts, kindly contact the sales point where you made your purchase.
CAUSE
Excessive performance request, check for any
leaks from the couplings and/or pipes. Intake
filter may be clogged.
Tripping of the thermal cutout due to overheating
of the motor.
Tripping of the thermal cutout due to overheating
of the motor (removal of the plug with the
compressor running, low power voltage).
Irregular functioning of the compressor or
breakage of the pressure switch.
10
REMEDY
Replace the seals of the fitting, clean or replace
the filter.
Clean the air ducts in the conveyor. Ventilate
the work area.
Activate the on/off switch. Ventilate the work
area. Wait a few minutes. The compressor will
restart independently. Remove any power cable
extensions.
Remove the plug and contact the Service
Center.