It is possible to solve this trouble following next steps:
1. Disassemble the set of the outlet valve using a 5 mm Allen. This "set of the outlet valve" has four
pieces:
- Ref.- 81144 - Grooved stud
- Ref.- 81163 - Spring
- Ref.- 81155 - O-ring gasket
- Ref.- 81158 - Plug
2. Check that these four pieces are in good conditions and clean any dirtiness they could have (pro-
bably this dirtiness blocked the outlet valve).
3. Clean the place of the outlet valve using a cylindrical brush or using compressed-air.
4. Assemble back the four pieces in the same way screwing them on without forcing the spring, it
means, do not screw on to the end. If the spring is forced, the flow of water will be blocked by
it. A correct adjust could be tested pumping water.
For adjusting the set of the outlet valve, it could be screwing on until feel the spring power (do
not continue screwing on) and then loosen one or two turns.
5. Pump water to check the correct adjustment of the outlet valve.
a) If the handle is too hard, loosen the outlet valve using a 5 mm Allen a little bit.
b) If the valve loses pressure, screw on a little bit this valve using a 5 mm Allen.
81144
81163
81155
81158
8
Grooved stud
Spring
O-ring gasket
Plug
A
B
C
D
A
B
C
D

Publicidad

loading

Este manual también es adecuado para:

60009