Important: The limit switch acts closing, never let that the door stop crashing with the
mechanic limit (for example a wall or a metallic column). Let allways a space between
this and the door. Check that this occur too when the door is moving automatically. If
not, move the magnet to forward in order to the motor stops the door before (take the
inertia of the door account).
Spacer plate
Place the piece between the limit
switch bracket and the rack as shown
in the image.
3.3.6 Control board wiring
Figure 10
The control board have some LEDS to indicate the outputs state to find easily
troubles: El cuadro de maniobras está dotado con una serie de leds (luces) que
indican el estado de las entradas para encontrar más fácilmente eventuales
anomalías de instalación:
LED nº 1: open button Normally Open
LED nº 2: close button Normally Open
LED nº 3: stop button Normally Open
LED nº 5: low limit switch (right) Normally Close
LED nº 7: high limit swich (left) Normally Close
LED nº 9: Photocell contact Normally Close
11