Smartpack Advanced Features; Advanced Menu - ETC SmartPack Manual Del Usuario

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

SmartPack Advanced Features

To enter Advanced Menu:
1. Scroll to General Settings.
2. Scroll to Menu Mode, press
3. Scroll to Advanced Menu, press and hold for 5 seconds.
DMX Patch:
1. Scroll to DMX, press
2. Scroll to DMX Patch, press
3. Use + or - to increase dimmer or channel, press to save a
value.
DMX Loss Behavior
Set the DMX Loss Behavior to either Hold Last Look, Wait and
Fade, or Fade to Preset.
Hold Last Look - holds last valid DMX values infinitely.
Wait and Fade - maximum wait time is 59 minutes, 59 seconds,
then fades to zero.
Fade to Preset - set a wait time and select a preset to fade to.
Set DMX Loss Behavior (Hold Last Look):
1. Scroll to DMX, press
2. Scroll to DMX Loss Behavior, press
3. Select to desired Loss Behavior and set values.
P r e s e t s
When you record a preset Smartpack will snapshot any level,
whether set in the test menu or by a DMX input. If both are present
it will record all levels. If you record a new preset using the same
preset number SmartPack will record over the previous levels.
Presets are activated in the default fade time of 3 seconds.
Record a Preset (snapshot):
1. Set dimmer levels with external DMX source or set a test
level
2. Scroll to Presets menu, press
3. Scroll to Record Preset, press
4. Scroll to select a Preset number, press
5. Press
S e q u e n c e r
Sequence plays a series of recorded presets (sequentially). The
order of execution is based on the first preset and the length is
determined by the number of steps in a Sequence. A fade time
and a hold time can be set for each step (Preset) in a Sequence.
The default Fade time is 3 seconds, the default Hold time is
0 seconds. A sequence can be set to Loop continuously.
F l u o r e s c e n t S t a r t V o l t a g e
Fluorescent circuits provide a dimmable output in the 5% to 100%
control range. Trim the minimum RMS output voltage to match
your specific ballast.
The default voltage is 47% of your mains voltage, change the
Start Voltage value to make the minimum start voltage lower or
higher.
Consult the ballast manufacturer's documentation for the
appropriate minimum start voltage.
P o w e r U p B e h a v i o r
If a Preset or Sequence is playing, and power input is interrupted,
the Power Up Behavior setting ensures that SmartPack will
respond predictably when power is restored.
There are two options for Power Up Behavior:
1. Select Normal so that SmartPack will restore to a blank state
(nothing playing).
2. Select Previous State so SmartPack restores to playing the
same Preset or Sequence as it was prior to power loss
SmartPack User Manual

Advanced Menu

DMX 001> 012
Level:
DMX
DMX Start Address
Set Start Address
DMX Patch
Set DMX Patch
DMX Loss Behavior
Hold Last Look
Wait and Fade Out
[
Wait Time
Fade to Preset
Preset Number
DMX Mode
Start Address
DMX Patch
Presets
Activate Preset
Number
Preset Activated
Deactivate Preset
Preset Deactivated
Record Preset
Preset Number
Preset Recorded
Sequencer
Start Sequence
Sequence Started
Stop Sequence
Sequence Stopped
Setup Sequence
Number of Steps
Loop?
Setup Timing
Preset / Step
Fade Up
Fade Down
Hold Time
Sequencer Status
Sequence Active, Sequence Inactive
Step: __ Wait: __, Step: __ Fade:__
Dimmer Curves
Dimmer Num__, Mod SQR Law
Dimmer Num__, Linear
Dimmer Num__, Flourescent
Set Start Voltage , Flourescent
Dimmer Num__, Switched
Dimmer Num__, Preheat
Set Preheat Level, Preheat__
General Settings
Set Language
LCD Backlight
Menu Mode
Restore Defaults
Deep Clear System
Software Version
Power Up Behavior
Diagnostics