3 INSTALLATION
Control Unit
Install the control unit on a wall using the bracket and the screws supplied. Choose
a place for easy access and reading. The control unit must be placed at 1.5 meters
max. away from the electrolytic cell. Choose a place with good ventilation and
protected from possible flooding, rain, water leaks or splash.
Please, make sure that a residual current circuit breaker protects
the installation. This is a legal requirement and very important for
your safety.
Connect the earth wire (yellow and green) of the 230 VAC power supply cable to
the earth of the swimming pool electric panel. Connect the phase (brown) and the
neutral (blue) to the output contacts of the pump contactor in such a way that the
chlorinator will be powered only when the pump is working. Connect the chlorinator
wires to non occupied contacts. Do not use the contacts in use by the pump.
This will prevent the chlorinator to be electrically connected to the pump when the
contactor is switched off what could cause serious damage. Verify that the
chlorinator switches off itself when the pump stops. This operation should be
performed by a professional.
The chlorinator should be powered to 230 VAC only if the pump is
working and the water is flowing through the cell. Please pay
special attention if your installation is three-phase (380 VAC pump)
Cell housing
The cell housing must be installed in the return flow to the swimming pool and as
19