RECYCLING
In accordance with the European Directive 2002/96/CE relating to waste electrical and electronic
equipment (WEEE), and its transposition into national legislation,
appliances
(including high pressure cleaners)
to recycling which respects the environment
Their packaging or accessories must also be subjected to a suitable recycling process.
DO NOT DISCARD ELECTRICAL APPLIANCES WITH HOUSEHOLD WASTE.
Recycling of raw material rather than waste disposal.
The VIRAX high pressure cleaner complies with the RoHS European directive
(2002/95/CE).
MALFUNCTION / CAUSES / SOLUTIONS
SYMPTOMS
There is no water at the lance outlet and / or no
water at the accessory outlet
It is not possible to switch to HP or LP on the
lance / Handle "hard" to turn, or loose
Pump is noisy: Hose vibration.
The device does not switch off automatically
when I release the trigger of the gun.
Detergent is not released.
Water leak under the appliance: At the cylinder
head.
The device stops unexpectedly or after
INTENSIVE use
The motor "groans" but does not start
English
must be collected separately and submitted
.
PROBABLE CAUSES
Problem with water supply
Pump inlet filter or faucet clogged
Two channel lance set to LOW PRESSURE
By-pass untightened (low pressure 60 bar)
Leak on an accessory
Needle valve blocked
Handle overtightened
Valves blocked
Internal water seals worn
Pump inlet filter clogged
Leak on an accessory
Automatic stop microswitch damaged or not
working properly.
Detergent filter / Injector / Pipes clogged
Tank EMPTY
Worn or damaged seals
Cylinder head bent out of shape due to freezing
Use of a NON COMPLIANT extension
Motor overheating: Thermal cut-out tripped
Problems with the electric supply
Problem with network voltage
Problem with motor ROTOR/STATOR
31
out of order electrical
POSSIBLE SOLUTIONS
Check water supply
Clean the filter(s)
Pull the head towards you: HP position.
Tighten the By-pass
Check all connections
Try to unblock it with a pair of pliers
Contact VIRAX after sales service
Clean the filter(s)
Check all connections
Contact VIRAX after sales service
Check & Rinse the system with water.
Check the level in the tank
Contact VIRAX after sales service
Plug directly into the power outlet.
Allow the device to cool for 5 minutes and restart.
Check the power outlet and / or the circuit breaker.
Check if it is > to 215 V.
Contact VIRAX after sales service