PURPOSE
The HIGH FREQUENCY ELECTROSTIMULATION DEVICE HFI-10 is a cosmetic device used in SPA salons, beauty salons
or fitness clubs. It is designed to generate high-frequency therapeutic micro-currents, in order to improve cell metabolism,
clean and disinfect the skin, enhance microcirculation, improve the absorption of active principles from cosmetics, as well as
to tone up the skin and reduce wrinkles.
In case of damage resulting from an improper use of the device, the user shall assume all liability.
BEFORE FIRST USE
On receipt of the parcel, make sure the packaging is undamaged before opening it. If the packaging is damaged, please contact
your transport company and distributor within 3 days. Be as specific as possible when describing the damages. Do not turn
the package upside down! When transporting the package, please ensure that it is kept horizontal and stable. The packaging
materials (cardboard, plastic straps, polyurethane foam) should be kept at hand, so that the device can be sent back to the
service centre, if needed, in the best conditions!
ENVIRONMENT OF USE
The room temperature must not be higher than 45°C and the relative humidity should be under 85%. Keep the device away
from hot surfaces. Operate the device on flat, stable, clean, refractory and dry surfaces, out of the reach of children and
people with mental disabilities. Make sure that the power outlet is always within reach. The power outlet must be properly
grounded and match the technical requirements of the device.
OPERATING PRINCIPLE
1
1
1.
main switch
2.
„spoon" electrode – to treat hard to reach areas
3.
„mushroom" electrode – to treat cheeks, forehead, neck, chest, back.
4.
"spot" electrode – to treat hard to reach areas
5.
"comb" electrode – to treat the scalp
APPLICATION
Before using the device, prepare the skin properly – it should be dry (wet skin may damage the glass electrode).
Remove the device from the box WITH DRY HANDS. Put the switch in the off position.
Select the appropriate electrode and insert its metal tip in the device output. Please note that both the electrode and your
hands must be completely dry.
Turn on the device by rotating the main knob clockwise, until you reach the desired intensity. Start with the lowest intensity
- it can be increased gradually by turning the knob clockwise. Never touch metal objects with the device. Before use, the
person on whom the treatment is to be performed should remove all metal items (such as jewellery, etc.).
Place the glass electrode to the skin and adjust electrical intensity. Please note! It is forbidden to use the electrodes on
eyelids! Any treatment around the eyes should be done with extreme caution, only at the lowest intensity. You may want
to combine the use of this device with skin cosmetics (such as masks): if so, make sure they are oil-based (not water-based)
and acohol-free.
Rev. IV 2016
2
3
4
5
8
The device can produce sparks. To avoid them, always use the lowest electrical intensity before putting the electrode on the
skin. Then increase gradually the intensity. Before removing the electrode from the skin, set the intensity back to its minimum
and turn off the device.
WARNING! Never insert or remove glass electrodes when the device is on!
TRANSPORTATION AND STORAGE
When transporting the device, avoid shaking it, dropping it and turning it upside down. Store it in a cool, dry place, free of
any corrosive gas.

CLEANING AND MAINTENANCE

Unplug the device before cleaning.
Use a mild, non-corrosive detergent.
Let the device dry before using it again.
Store the device in a dry, cool location, free from moisture and direct sunlight.
The quartz balls can be washed in a sieve under running water with a mild detergent.
REGULAR CONTROL OF THE DEVICE
Regularly ensure that the device is in good condition. Should it be damaged, please stop using it immediately and contact
your customer service to solve the problem.
What to do in case of problem?
Please contact your customer service and prepare the following information:
Invoice number and serial number (the latter is to be found on the technical plate on the device).
If relevant, a picture of the damaged, broken or defective part.
It will be easier for your customer service advisor to identify the source of the problem if you give a detailed and
precise description of the matter
The more details you give, the quicker the customer service will be able to solve your problem!
CAUTION: Never open the device without the authorization of your customer service. This may void the guarantee!
Rev. IV 2016
9
9

Publicidad

Tabla de contenido
loading

Tabla de contenido