Setting with service remote control DO-5.1 S
Parameter
Function
Sensor runtime in days
Number of full and partial flushes
Number of automatically triggered flushes
System info
Number of intermittent flushes triggered and externally triggered flushes
Display of the min. and max. time in sec. between individual flushes
Display of the average daily number of full and partial flushes
Displace of code number and software ID:
Edge lighting flashes red, once right, once left.
Range test
During detection of the 0.8 m range, the full flush button shines in blue.
During detection of the 0.5 m range, the full flush button shines in green.
Is used for the automatic setting of the presence detection range. If this function is started, no
persons or objects may be within the desired detection range, max. 1.5 m.
Range W setting
Doors which project into the detection area must be closed immediately after activation (e.g. toi-
let cabin), the flush panel is ready for use after 30 seconds and the room can be entered again.
Default setting
All parameters are reset to the default setting.
OK setting
Open data recording
and menu
Set parameter
and confirm by
pressing the
OK key
16
Select
parameter
Send setting
Confirm remote
control with
send OK