11.
Problem handling
Interference
No function
Teach-in run not
possible
Teach-in run starts
but is not completed
Teach-in run starts
again
NOTE
Contact specialist dealer if the fitting is still defective or other problems
occur after the prescribed remedial measures have been carried out!
Cause
No power
Connectors have no
contact
Wrong wiring
After 2 minutes of
continuous operation, 8
minutes of stop time
Matching of remote
control / control unit not
performed
Battery in remote
control empty or
missing
Mechanical force of
the fitting has not been
adjusted to weight of
flap
Blackout
Remedy
Check whether the control
unit is plugged in to the
power supply
Check that all connectors
have a reliable
contact
Check whether the colour
assignments of the
connecting wires to the
connectors correspond
with the specifications on
the control unit
Wait for 8 minutes
Perform matching of
remote control/ control
unit, see chapter 4.1,
page 19
Insert new battery, see
chapter 8, page 10
Set mechanical force in
accordance with point 12
of E-Verso / E-Strato / E-
Senso installation
instructions
Perform a teach-in run,
see chapter 7., page 21
23/84