Anleitung HK-G 55 -12 sprachig
1
Adjustment of the shoe (cutting angle)
1. Release the 2 lock screws 1
2. Adjust the shoe to the desired angle between 0 and 45°.
3. Tighten the lock screws 1.
1
Fitting and removing the splitter
1. Undo the recessed head screws 1 and remove.
2. Pull the splitter down and out.
3. Fit in reverse order.
29.02.2000 9:21 Uhr
Important!
Pull out the plug before
making any changes to the
circular saw!
Changing the saw blade
1. Open the hinged guard hood 1 and hold.
2. Use the face spanner 2 to stop the saw blade from moving.
3. Undo the screw with the socket wrench 3.
4. Remove the flange 4 and the saw blade by dropping down
and out.
5. Clean the flange and insert a new blade. Note the direction
of rotation (see arrow on the guard hood).
6. Tighten the screw and check for concentricity.
Switching on and off
To switch on:
To switch off:
2
Seite 9
Switching on
Before pressing the On/Off
switch, check that the saw blade
is properly fitted, that the moving
parts run smoothly and that the
clamping screws are tight.
1
4
2
3
Press the interlock button 3 and the switch 4
simultaneously.
Release the interlock button and the switch.
3
4
GB
9