We strongly recommend reading carefully the entire manual in order to ensure the best possible use and the
Any non compliance with the assembly, installation and operating instructions is the sole responsibility of the
THIS STOVE MUST BE INSTALLED IN COMPLIANCE WITH THE CURRENTLY ENFORCED D.T.U.
All local, national, and European regulations must be respected when using this appliance.
WE RECOMMENDED ASKING A QUALIFIED PROFESSIONAL TO INSTALL THE STOVE.
1 - DESIGNATION
The stove C07728 is in line with French standard NF EN 13240.
There is constant heating system with grating combustion designed exclusively for wood burning, inside a
semi-closed combustion chamber.
2 - NOMINAL CALORIFIC POWER AND SLOW BURNING AUTONOMY
- Nominal calorific power according to standard NF EN 13240 during normal burning test: 12 kW.
The appliance can either be used in intermittent mode or in continuous mode.
Intermittent and continuous running :
The intermittent running needs a reload every three quarters of an hour.
This choice of operation is to be favoured as it is environmentally-friendly.
The appliance can also ensure a continuous running when the intemittent constraints can't be respected or
when a reduced power is wanted.
Nominal calorific power with an intermittent working:
. Obtained with a 12 Pa draught with a fire lasting ¾ of an hour, with a loading of 2,84 kg of hard wood
(hornbeam, oak ...) in the form of 2 split wood logs of about 9 cm diametre.
. To get this heat power, reload on an ash bed of about 500 g that is to say 4 cm thick.
. The given power is the average power obtained in the tests with the the air intake damper opened to its
maximum.
The slow combustion :
. Obtained with a 6 Pa draught, with the air intake damper closed.
. Reload on an ash bed of about 500 g (4 cm thick).
. It can last over 10 hours with an unsplit log of hard wood of a large diametre weighing between 6 and10 kg.
Normal speed conditions allow to get a maximum power which is not to be exceeded to guarantee a running in
complete safety.
The maximum loading is 15 kg of wood
highest satisfaction from your Deville stove.
person performing any operation on the stove.
SPECIFICATIONS.
The appliance must not be modified.
12