DMM51FSG Manual FINAL-091908:Layout 1
B-2 ALTERNATING CURRENT VOLTAGE (AC VOLTAGE)
Range
200mV
2V
20V
200V
750V
INPUT IMPEDANCE: All ranges are 10MΩ.
FREQUENCY: 40Hz-400Hz.
OVERLOAD PROTECTION: 200mV is 250VDC or AC RMS.
DISPLAY: Average Value (RMS of Sine Wave).
B-3 DIRECT CURRENT CURRENT (DC CURRENT)
Range
20 A
200 A
2mA
20mA
200mA
2A
10A
OVERLOAD PROTECTION: 2A/250V fuse (below 2A range) and 10A/250V fuse
MAX CURRENT INPUT: 10A
MEASURING VOLTAGE DROP: Full range is 200mV.
B-4 ALTERNATING CURRENT CURRENT (AC CURRENT)
Range
200 A
2mA
20mA
200mA
2A
10A
OVERLOAD PROTECTION: 2A/250V fuse (below 2A range) and 10A/250V fuse
MAX CURRENT INPUT: 10A
MEASURING VOLTAGE DROP: Full range is 200mV.
DISPLAY: Average Value (RMS of Sine Wave ).
Resolution
100 V
± (1.2% rdg + 3 digits)
1mV
10mV
± (0.8% rdg + 3 digits)
100mV
1V
± (1.2% rdg + 3 digits)
All other ranges is 750Vrms or 1000Vp-p.
Resolution
0.01 A
0.1 A
1 A
10 A
100 A
1mA
10mA
(10A range).
Resolution
0.1 A
± (1.8% rdg +3 digits)
1 A
10 A
100 A
± (1.8% rdg +3 digits)
1mA
± (1.8% rdg +3 digits)
10mA
(10A range).
9/19/08
Accuracy
DMM51FSG
Accuracy
DMM51FSG
± (2% rdg +5 digits)
± (0.8%rdg +1 digit)
± (0.8% rdg +1 digit)
± (1.5% rdg +1 digit)
± (1.5%rdg +1 digit)
± (2%rdg +5 digits)
Accuracy
DMM51FSG
± (1% rdg +3 digits)
± (1% rdg +3 digits)
± (3% rdg +7 digits)
4:03 PM