10.4 Screw the flow volume regulator up to the stop limit.
10.5 Remove the flush plug (c).
10.6 Screw-in the self-closing cartridge element (d).
10.7 Use the flush plug as an assembly tool to tighten the self-closing cartridge element.
☞
Important!
• Tighten the self-closing cartridge element carefully.
• Keep the flush plug in the in-wall installation box as a tool for any possible
dismounting of the self-closing cartridge element at a later time.
10.8 Remove the protective earth conductor cable (e).
10.9 Remove the mounting frame from the cover plate by loosening the set screw.
10.10 Screw the mounting frame on horizontally.
10.11 Slide the plastic hoses (h) into the rings until there is a noticeable resistance.
☞
Important!
Make sure the rings have the same-coloured markings.
f: green
g: white
10.12 Adjusting the flushing volume (see
10.13 Adjusting the flushing flow (see
10.14 Open the flow volume regulator. (The water flow must stop after a short period).
10.15 Hang the cover plate (i) on the mounting frame (l).
10.16 Attach the cover plate with the grub screw (k).
11. Function
1. Start
2. Stop
Automatic according to set flushing volume.
A: Flow pressure 1.0 – 4.0 bar
B: 2 – 4 l for each actuation
C: 0.30 – 0.70 l/s
12. Adjusting the Flushing Volume
12.1 Remove the cover plate (see
12.2 Adjust the flushing volume.
+ more
– less
12.3 Reassemble in the reverse order.
6
Chapter
12.).
Chapter
13.).
Chapter
14.).