Explanation of signs
The triangle containing a lightning symbol is used to indicate whenever your health is at risk (due to electrocution, for
example).
An exclamation mark in a triangle indicates particular risks in handling or operating the appliance.
Specifications
Feature: This machine comes with elapsed time display and intelligent temperature control display to ensure the
lamp life. Use ultra-quiet motor to meet the needs of the modern stage.
Voltage: ................................................................................................................. 220-240V∼ 50/60Hz
Fuse: ............................................................................................................................... 2A 250V
Power consumption: ............................................................................................ 70W (0.30A), Max. at 230V
Light source: .......................................................................................... 7pcs of 10W 4 in 1 LED, RGBW
Pan: .................................................................................................................... 180°, 360°, 540°
Tilt: ................................................................................................................................ 90°, 180°
Function: .......................................... Sound control, Auto-run, Master/Slave, DMX512, Strobe
Max. Ta ................................................................................................................................. 40°C
Channel: ...................................................................................................8 or 13 DMX channels
Data input.................................................................................... Locking 3-pin XLR male socket
Data output ............................................................................ Locking 3-pin DMX female socket
Data pin configuration ................................................................. Pin1 shield, pin 2 (-), pin 3 (+)
Dimensions .......................................................................... 180 (L) x 175 (W) x 235mm (H) mm
N.W/G.Weight: .......................................................................................................... 2.7kg/3.6kg
2. SETUP
Disconnect the power cord before replacing a fuse and always replace with the same type fuse.
Fuse Replacement
With a flat head screwdriver wedge the fuse holder out of its housing.
Remove the damaged fuse from its holder and replace with exactly the same type of fuse.
Insert the fuse holder back in its place and reconnect power.
The fuse is located inside this compartment. Remove using a flat head screwdriver.
Fixture Linking
You will need a serial data link to run light shows of one or more fixtures using a DMX-512 controller or to run
synchronized shows on two or more fixtures set to a master/slave operating mode. The combined number of
channels required by all fixtures on a serial data link determines the number of fixtures that the data link can
support.
Important: Fixtures on a serial/data link must be daisy chained in one single line. Maximum recommended serial
data link distance: 500 meters (1640 ft.) Maximum recommended number of fixtures on a serial data link: 32 fixtures
Data Cabling
To link fixtures together you must use data cables. If you choose to create your own cable, please use data-grade
©Copyright LOTRONIC 2018