7 Timeout Programming
Description
Phase
Press shortly the programming button of the MINI-RX. The LED on the receiver will blink and the
1
buzzer will perform one beep every 2 seconds.
Hold down the programming button of the MINI-RX for more than 3 seconds. The LED on the
2
receiver will perform another blink and the buzzer another acoustic warning.
For the "Motor Control" mode go to step 5.
Press the programming button a number of times equal to the hours of activation you want to
program:
1 pressure -> 0 Hour
3
2 pressures -> 1 Hours
...
10 pressures -> 9 Hours
The receiver will blink 2 times and the buzzer will perform 2 beeps at each button pressure.
Confirm the hours of operation by holding down the button programming of the MINI-RX for
4
more than 3 seconds. The receiver will perform a blink and an acoustic warning (long).
Press the programming button a number of times equal to the minutes of activation you want
to program::
1 pressure -> 0 minute
5
2 pressures -> 1 minutes
...
60 pressures -> 59 minutes
The receiver will blink 3 times and the buzzer will perform 3 beeps at each button pressure.
Confirm the minutes of operation by holding down the button programming of the MINI-RX for
6
more than 3 seconds. The receiver will perform a blink and an acoustic warning (long).
Press the programming button a number of times equal to the seconds of activation you want
to program:
1 pressure -> 1 second
2 pressures -> 2 seconds
7
...
59 pressures -> 59 seconds
The receiver will blink 4 times and the buzzer will perform 4 beeps at each button pressure.
(NOTE: If you try to set a time of 0 seconds, the MINI RX will set a default time of 60 seconds in
the Light Control mode and 240 seconds in the Motor Control Mode).
Confirm the seconds of operation by holding down the button programming of the MINI-RX for
8
more than 3 seconds. The receiver will perform a blink and an acoustic warning (long).
9
End
22
Example