Mounting The Device - HQ-Power VDL500SMM Manual Del Usuario

Ocultar thumbs Ver también para VDL500SMM:
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

• Use the original packaging if the device is to be transported.
• All modifications of the device are forbidden for safety reasons.
• Only use the device for its intended purpose. All other uses may lead to short circuits, burns,
electroshocks, crash, etc. Using the device in an unauthorised way will void the warranty.
4. Installation
Refer to the illustration on page 2.
1
nozzle
2
housing
a. Smoke Liquid
• Only fill the tank when the device is unplugged from the mains.
• Use only non-inflammable smoke liquid without oil or grease. Any other liquid may damage the device
and void the warranty.
• Only fill the tank with specially developed water-based smoke liquid:
VDLSL1: 1 litre of standard smoke liquid
VDLSL5: 5 litres of standard smoke liquid
VDLSL5H: 5 litres of high density smoke liquid
VDLSLHT5: 5 litres of professional high density smoke liquid
• Procedure:
1. Make sure the device is switched off and disconnected from the mains.
2. Unscrew the cap of the tank (figure above #4) on the top of the device.
3. Carefully pour the smoke liquid in the tank.
4. Reposition the cap and fasten it.
Remark: Do not operate the device when the tank is open.
b. Fuse
• Only fit or replace a fuse when the device is unplugged from the mains.
• Replace a blown fuse with a fuse of the same type and rating (see "Technical Specifications"):
1. Make sure the device is switched off and disconnected from the mains.
2. Unscrew the fuse holder at the back with an appropriate screwdriver.
3. Remove the old fuse and install a new one.
4. Replace the fuse holder and fasten it with the screwdriver.
c.

Mounting the Device

• Have the device installed by a qualified person, respecting EN 60598-2-17 and all other applicable
norms.
• The construction to which the device is attached should be able to support 10 times the weight of the
device for one hour without deformation.
• The installation must always be secured with a secondary attachment e.g. a safety cable (VDLSC7 /
VDLSC8).
• Never stand directly below the device when it is being mounted, removed or serviced. Have a qualified
technician check the device once a year and once before you bring it into service.
• Install the device in a location with few passers-by that is inaccessible to unauthorised persons.
• Overhead mounting requires extensive experience: calculating workload limits, determining the
installation material to be used... Have the material and the device itself checked regularly. Do not
attempt to install the device yourself if you lack these qualifications as improper installation may result
in injuries.
• Adjust the desired inclination angle via the mounting bracket and tighten the bracket screws.
• Make sure there is no flammable material within a 0.5m radius of the device.
• Have a qualified electrician carry out the electric connection.
• The installation has to be approved by an expert before the device is taken into service.
5. Use
Make sure the power switch is set to OFF. Connect the device to the mains. Flick the power switch to ON.
After a certain warm-up time (3 to 4 minutes), the device is ready to be used.
Use the button on the remote control to select continuous smoke output. The stand-by lamp may be off
and the smoke emission may stop even though you are holding the button – this means the device is
heating up again and will be ready to operate in approximately 2 minutes. This process guarantees an
optimum vaporization temperature and the best possible smoke emission.
23.12.2010
VDL500SMM
3
mounting bracket
4
tank cap
4
Rev. 01
©Velleman nv