5.1.1.2
Ego 2 Tech
Pumps have 3 preconfigured curves of proportional pressure, constant
pressure, fixed speed modes, auto, and night mode. The lit symbol represents
the selected mode and curve.
The pump also shows the current power consumption, current pressure, and
flow. Values on the display interchange every 5 s.
Auto mode
Power, head and flow display
5.1.2
BUTTON
A short press on the button will change the pump curve from the first to the
second and then to the third curve. After the third curve is reached and the
button is pressed again, the pump mode will change and the first curve will be
selected. If the pump is in standby, then it will start with a short press.
A long press will turn on standby mode. In this mode, the pump will occasionally
turn on, with minimal speed. The pump will blink its current mode.
Auto mode does not have any pump curve to select.
20
Default view
Pump modes
Proportional
Constant
pressure
pressure
Constant
Night mode
speed
Pump curve
Third curve (orange)
Second curve (green)
First curve (blue)