Directive 97/23/EC for pressure equipment (PED). The compliance with this requirement is assured by
a special electronic device that constantly checks:
• that for temperatures above 110 °C/230 °F, the pressure set is below 32 bar/464 psi;
• that for pressures above 32 bar/464 psi, the temperature set is no greater than 110 °C/230 °F.
If the above limits are exceeded, the burner stops and the warning light (48) comes on.
Steam operation will only resume if the pressure is reduced to below 32 bar/464 psi.
• Turn the high pressure cleaner on again by turning the master switch (1) to
to below 32 bar/464 psi by turning the knob (8) anticlockwise.
• Set the temperature between 110°C/230°F and 140°C/284°F using the temperature adjustment
knob (25).
• Press the cleaner gun lever (24) and wait for steam to be produced.
• If the burner stops working during use of the cleaner and the warning light (32) lights up, turn the
knob (8) anticlockwise to lower the pressure below 32 bar/464 psi.
• You can check the pressure level on the pressure gauge (10).
• When the fuel is low, the burner will stop working and the warning light (28) will light up.
• The burner will only start working approximately 3 seconds after the cleaner gun has been opened
and will stop working when the cleaner gun is closed or when it reaches the set temperature.
• If the flame goes out, the burner will stop working and the warning light (33) will light up.
The Manufacturer recommends the use of detergents which are at least 90% biodegradable.
Refer to the label on the detergent for instructions on how to use it.
• Turn the master switch (1) to "0" .
• Put the hose (37) in the external tank (FIG. 5) which has already been prepared with detergent to the
strength required: in this case too, follow the instructions given for the dosage on the detergent pack
label.
• Turn the knob for adjusting the detergent (20) anticlockwise.
Switch the cleaner on again by turning the master switch (1) to
•
lever (24) to start distribution of detergent (these versions distribute the detergent at high pressure).
The KF STEEL models
preventing the build up of lime scale as a result of using the cleaner with hot water.
• Turn the master switch (1) to "0". Unscrew the cap (9) and fill the tank with liquid, making sure it does
not spill over. We recommend using a funnel reserved exclusively for this purpose (maximum tank
capacity 2 L/0.53 US gal). Replace the cap and check the level regularly.
Only use water softeners recommended by the Manufacturer.
• Release the cleaner gun lever (24) to stop the high pressure jet and the high pressure cleaner moves to
by-pass operating mode, and if it remains in this condition it will stop automatically after approximately
13 seconds (Total Stop).
• The cleaner will resume normal operation the as soon as the lever on the gun is pressed.
WARNING
• If you stop the high pressure jet and put the gun down, enable the locking handle (27). STEP K IN FIG. 4.
26
OPERATION WITH DETERGENT
OPERATION WITH WATER SOFTENER
of the product are fitted with a high-performance water softener as standard,
STOPPING THE CLEANER – TOTAL STOP MODE
and set the pressure
or
; operate the cleaner gun