1606-XLS80E Power Supply Instruction Manual
Technical Data
Output Voltage
Factory Set
typ.
Output Current
min
min
Output Power
min.
min.
Output Ripple
max.
Over-voltage Protection
max.
AC Input Voltage
-
AC Input Current
max.
DC Input
-
DC Input Current
max.
Power Factor
typ.
AC Inrush Current
max.
max.
max.
Efficiency
typ.
Losses
typ.
Hold-up Time
typ.
typ.
typ.
Capacitive Loads
-
Inductive Loads
-
Limited Warranty
-
Functional Diagram
L
Input Fuse
Input Filter
N
Input Rectifier
Inrush Limiter
Transient Filter
Temper-
Output
ature
Power
Shut-
Manager
down
Overload Performance
The unit is designed to support loads with a higher short-
term power requirement without damage or shutdown.
28V
24V
20V
16V
continuous
12V
Short
term
8V
4V
0V
0A
1A
2A
3A
4A
5A
Output characteristic (typ.)
Curve is valid for the 24V unit. Units with
output voltages other than 24V have an
equivalent and proportional performance.
Environment
Operational temperature
Storage temperature
Humidity
Vibration sinusoidal
Shock
Allowed output current versus
the ambient temperature
Ambient temperature is defined
2cm below the unit.
1606-XLS80E
DC 24-28V
24.1V
3.4-3.0A
5.0-4.5A
80W
120W
50mVpp
36Vdc
AC 100-240V
, 50-60Hz
-15/+15%
1.8-1.0A
DC 110-300V -20/+25%
0.85-0.3A
0.55-0.47
2
6A peak, 2A
s
2
7A peak, 2A
s
2
13A peak, 2A
s
88.7 / 90.0%
10.4 / 9.1W
21ms
35ms
167ms
No limitations
No limitations
1 year
Output
Voltage
Regulator
Output
Power
Filter
Converter
Output
Output
Voltage
Over-
Monitor
Voltage
Protection
8s
7s
6s
5s
4s
3s
2s
1s
0s
110% 120%
130% 140%
6A
Bonus time
Duration until the output starts dipping.
Bonus Time is hardware controlled.
min. / typ. / max.
-25 to +70°C
De-rate above +60°C
-40 to +85° C
Storage, transport
5 to 95% RH
No condensation allowed
2g
IEC 60068-2-6
15g 6ms, 10g 11ms
IEC 60068-2-27
150%
for ty p. 4s
125%
100%
continuous
75%
50%
Ambient Temperature
25%
0%
-40°C -20°C 0°C
20°C 40°C 60°C 80°C
externally adjustable
at full rated load
continuous
for typ. 4 sec
continuous
for typ. 4 sec
BW DC to 20MHz
TN, TT and IT mains
at 100 - 240Vac
at 110 - 300Vdc
at 100 - 230Vac
at 100Vac
at 120Vac
at 230Vac
at 120 / 230Vac
at 120 / 230Vac
at 100Vac
at 120Vac
at 230Vac
Dielectric Strength
Input
L
V
OUT
N
+
A
+
-
Earth
-
Over-
load
DC
ok
Repetitive pulse loading:
P
OUT
max.
150%
100%
150% 160%
0%
Protection
Output
Degree of protection
Class of protection
Degree of pollution
Over-temperature protection
Output over-voltage protection
Over-voltage category
Penetration protection
Internal input fuse
External protection
Type tests and factory tests:
Conducted by the manufacturer.
Do not repeat test in field!
Field test rules:
Output
(1) Use appropriate test equipment which
+
apply the voltage with a slow ramp!
(2) Connect L and N together as well as all
-
output poles.
(3) Use only AC test-voltages with 50/60Hz.
The output voltage is floating and has no ohmic
reference to ground.
A
Type Test
60s
2500Vac
Factory Test
5s
2500Vac
Field Test
5s
2000Vac
Multiple pulses can be supported as long as the average
(R.M.S.) output current stays below the specified continuous
output current. If it is higher, the unit will respond with a
thermal shut-down.
P
T
T
PEAK
PEAK
0
P
0
Overload, no-load, short-circuit proof
IP 20
I
2
yes
yes
III
>3.5mm
T6.3A
The unit is tested and approved for branch circuits
up to 20A. External protection is only required, if the
supplying branch has an ampacity greater than this.
The minimum rating of an external circuit breaker or
fuse shall be 6A (B-characteristic) or 6A (C-
characteristic) to avoid a wrong tripping of the fuse.
B
C
3000Vac
500Vac
2500Vac
500Vac
2000Vac
500Vac
Examples for pulse load
compatibility:
P
P
T
T
PEAK
0
PEAK
0
120W
80W
1s
>25s
120W
0W
1s
>1.3s
120W
40W
0.1s
>0.16s
120W
40W
1s
>1.6s
t
120W
40W
3s
>4.9s
t
EN/IEC 60529
PE (Ground) connection required!
EN 50178, not conductive
Output shut-down with automatic restart
Output shut-down with automatic restart
EN 50178
e.g. screws, small parts ...
Device protection, not externally
accessible