Precautions On Setup - Maruyama MS313-A Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Points in Handling This Machine
○Spraying conditioners for crops from the fields of rice, crops from general vegetable fields, fruit
trees, mulberry, and trees
○Spraying antiseptic solutions or insecticides for cattle houses, chicken houses, and city sanitation
○Spraying liquid sterilizers ○Spraying water to crops from general vegetable fields or fields of rice
○Washing cattle houses, chicken houses, agricultural crops, and agricultural instruments
○Washing wall surfaces, etc. of building structures and protecting electric feeder lines from salt damages
CAUTION
Do not use strong acid, strong alkali, chemical solvents, and hot water. Damages of the power
atomizer or accidents may be caused.
WARNING
・When setting up this product with a motor, please contact the MARUYAMA service dealer.
・When driving this product using a V pulley or V belt, be sure to attach a cover over the rotary part so that it cannot
be easily touched during check.(Keep the cover being attached for operation and check. If the cover cannot be
installed, special considerations are required e.g. be sure to provide a fence around the working machine.)
・Be sure to "stop" this machine before check or adjustment.
CAUTION
・Set up the power optimizer within the ranges of the specified rotating speed, pressure, and water
volume.
If these ranges are exceeded during use, damages of the power atomizer or accidents may be
caused.
・The rated output of the motor must be at or above the specified power of the power atomizer.
Otherwise, its performance may not be exercised.
・Be sure to set up in such a way that the oil gauge on the power atomizer can be easily checked.
CAUTION
・To fasten this machine use bolts with proper sizes and properties. Install the machine securely.
If installation of the power atomizer or motor is unstable, vibration may occur and the power
atomizer may be adversely affected.
・Select the proper-size V pulley or V belt complying with the specified power.
・Use the size of the V pulley shaft hole or key groove matching the shaft.
Do not use any shaky V pulley hole or key groove because accidents may be caused by
detrimental vibration,
・The shaft end must slightly retract from the pulley surface. Tighten the volt accurately via the
washer. Use the V pulley retaining screw as necessary.
・Install the V pulley of the motor and the V pulley of the power atomizer on a straight line. If the V
belt is not set straight when viewed down, an unreasonable force is applied and the V belt may be
damaged or slip away.
・The V belt must not be too tight or too loose. If it is too tight, the bearing may be damaged. If it is
too loose, belt damages or slip-away may be caused.
・When using two or more V belts, use the same type and circumferential length.
・When replacing V belts, replace all at the same time.
Applications

Precautions on Setup

7

Publicidad

Capítulos

Tabla de contenido
loading

Este manual también es adecuado para:

Ms413-aMs513-aMs613-aMs653-aMs753-a

Tabla de contenido