Ways of releasing air
outdoors
Temporary installation.
Fig
7
and
8
.
Permanent installation
N.B.
Instructions for use
Connect the diffusion duct to the hot-air expulsion
duct.
Open the window slightly and feed the diffusion duct
through the gap.
Close the window as much as possible and secure
it in place using the suction pad provided.
The installation accessory for sliding windows that
comes with the appliance can also be used as
shown in figure
The appliance can be installed on a permanent basis
using window/wall Optional Accessory, (see
characteristics table at the end), available from your
supplier.
A hole must be made in the wall and the wall
accessory fitted in order to expel hot air, fig.
Store the diffusion duct away and connect the air
expulsion duct to the accessory.
Only the transparent end section of the accessory
is used when air is to be expelled through a window
on a permanent basis. A 10.5-cm. diameter hole
must be made in the glass in order to fit the
accessory, fig.
• Do not extend the expulsion duct more than
necessary (maximum length: 140 cm.) or bend it too
sharply. This can impede hot-air expulsion and
reduce cooling efficiency.
• There must be a distance of at least 70 cm. between
the floor and the end of the duct.
• Small rooms must be ventilated (e.g. leave the door
ajar) to avoid the formation of barometric
depressions. These can reduce cooling efficiency.
Warning!
Do not block the air inlets or outlets on your
appliance.