The type and serial number of the hood (on the chassis plate)
Information on the puchase

TROUBLE SHOOTER

PROBLEM
The hood is not working
The extraction of the range hood is not sufficient
ENVIRONMENTAL CONSIDERATIONS
PACKAGING
The packaging must be disposed of in accordance with local regulations on waste management.
SCRAPPING OF THE HOOD
The symbol
on the product or accompanying documentation indicates that this product may not be disposed of as household waste but must be
delivered to the nearest collection center for the recycling of electrical and electronic equipment.
POSSIBLE CAUSE
There is no power
The hood is not connected to the power supply Check that the hood is connected to the power
There is no power on the batteries
The pressure valve is blocked
The duct is jammed ore blocked
The filters are dirty and clogged.
THERMEX PASSAT
SOLUTION
Check the power supply to the hood. Disconnect
the power for approximately 5 minutes and con-
nect again to check if the fault is still there.
supply. Unplug for approximately 5 min, and
connect it again to check if the fault is still there.
Change the batteries in the remote control
Check if objects have fallen down on top of the
valve or whether the clamp around the valve is
tightened so hard that the valve cannot open.
Loosen the clamp or remove the object, if the
valve is blocked.
Check the duct, and repair if necessary.
Check if the filters are clean, and clean if neces-
sary. See the section cleaning and maintenance
in this manual.