Master BLP 11 Manual De Instrucciones página 13

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 29
►2.15.The heater must never be moved,
en
handled or subjected to any maintenance
it
interventions when it is running.
►2.16.In any condition of use or appliance
de
standstill, make sure that the flexible gas
es
hose is not damaged (crushed, bent,
fr
twisted, taught).
►2.17.If the smell of gas is perceived,
nl
switch the appliance off immediately,
pt
close the gas cylinder, disconnect the
mains plug and then contact the after-
da
sales assistance.
fi
►2.18.If the gas hose must be replaced,
no
only use the flexible type suitable for
the pressure used, referring to national
sv
regulations. The gas hose must measure
pl
1,5 m.
►2.19.When the appliance is controlled
ru
by a room thermostat (optional article),
cs
the heater can switch back on at any time
hu
i.e. when the temperature drops below
the threshold set.
sl
►2.20.When it is not used, disconnect
tr
the heater from the network plug, close
hr
the gas supply, disconnect the gas hose
from the heater and plug the gas inlet on
lt
the heater.
lv
►2.21.Have the after-sales assistance
check correct functioning of the heater
et
at least once a year and/or according to
ro
need.
sk
►►3. TYPE OF FUEL
bg
Use category I
3
uk
►►4. CONNECTION AND
bs
REPLACEMENT OF THE GAS
el
CYLINDER
zh
The gas cylinder must be replaced in the
open air, away from heat sources, in an
atmosphere without flames.
Only the following accessories must be
used for connection of the gas cylinder to
the heater:
B/P gas only.
•Liquid gas flexible pipe.
•Liquid gas pressure regulator complete
with safety valve.
CHECK THE INTEGRITY OF THE GAS
SUPPLY PIPE. IF THE GAS HOSE
MUST BE REPLACED, ONLY USE THE
FLEXIBLE TYPE SUITABLE FOR THE
PRESSURE USED, REFERRING TO
NATIONAL REGULATIONS.
►To connect the heater to the gas
cylinder:
ATTENTION: ALL
SINISTRAL, I.E. THEY ARE TIGHTENED
IN AN ANTI-CLOCKWISE DIRECTION.
►4.1.Screw the gas hose to the heater
fitting (Pic. 4).
►4.2.Install the pressure regulator on the
gas cylinder. Make sure there is a gasket
present on the regulator (if envisioned by
the type of connection) (Pic. 5).
►4.3.Connect the gas hose to the
pressure regulator (Pic. 6).
►4.4.Open the gas cylinder cock (Pic.
7).
►4.5.Press
the
button (Pic. 8). Check tightness of
fittings using soapy water: bubbles
indicate a gas leak (Pic. 9). Several
gas cylinders can be fitted together to
obtain greater autonomy. The use of
30 kg gas cylinders is recommended,
up to heating capacity of 33 kW. Over
the power of 33 kW use gas cylinders
with greater capacity. The use of gas
cylinders with suitable capacity is
recommended in order to prevent
problems due to lack of gasification
of the fuel. The correct functioning
pressure (see data plate applied to the
heater) is given by the regulator supplied
or an equivalent model.
THREADING
IS
regulator
release

Publicidad

Tabla de contenido
loading

Tabla de contenido