24.4 DEVICE PROFILE

DEVICE PROFILE DOCUMENT
Vendor Name:
INGETEAM S.A.
Device Name:
INGEPAC EF
Highest DNP Level Supported:
For Requests
Level 3
For Responses Level 3
Notable objects, functions, and/or qualifiers supported in addition to the Highest DNP Levels Supported (the complete list is
described in the attached table):
Maximum Data Link Frame Size (octets):
Transmitted
292
Received
292
Maximum Data Link Re-tries:
None
Fixed at
1
Configurable, range __ to __
Requires Data Link Layer Confirmation:
Never
Always
Sometimes
Configurable
Requires Application Layer Confirmation:
When reporting Event Data
When sending multi-fragment responses
Timeouts while waiting for:
Data Link Confirm
Complete Appl. Fragment
Application Confirm
Complete Appl. Response
Others
Sends/Executes Control Operations:
WRITE Binary Outputs
SELECT/OPERATE
DIRECT OPERATE
DIRECT OPERATE – NO ACK
Count > 1
Pulse On
Pulse Off
Latch On
Latch Off
Queue
Clear Queue
Reports Binary Input Change Events when no specific variation
requested:
Never
Only time-tagged
Only non-time-tagged
Configurable to send both, one or the other (attach
explanation)
Sends Unsolicited Responses:
Never
Configurable (attach explanation)
Only certain objects
Sometimes (attach explanation)
ENABLE/DISABLE UNSOLICITED
Function codes supported
Supports Collision Avoidance: Configurable
Default Counter Object/Variation:
No Counters Reported
Configurable (attach explanation)
Default Object
Default Variation ______
Point-by-point list attached
Sends Multi-Fragment Responses:
Ingeteam Power Technology S.A.
Manual de usuario
None
Fixed at _________
None
Fixed at _________
None
Fixed at __10 sg____
None
Fixed at _________
Never
Never
Never
Never
Never
Never
Never
Never
Never
Never
Never
_________
Yes
No
Device Function:
Master
Slave
Maximum Application Fragment Size (octets):
Transmitted
1024< >3072( configurable)
Received
1024
Maximum Application Layer Re-tries:
None
Configurable, range ____ to ____
Variable
Variable
Variable
Variable
Always
Sometimes
Always
Always
Sometimes
Always
Always
Sometimes
Always
Sometimes
Always
Sometimes
Always
Sometimes
Always
Sometimes
Always
Sometimes
Always
Sometimes
Reports time-tagged Binary Input Change Events when no
specific variation requested:
Never
Binary Input Change With Time
Binary Input Change With Relative Time
Configurable (attach explanation)
Sends Static Data in Unsolicited Responses:
Never
When Device Restarts
When Status Flags Change
Collision Avoidance Detection Method: DCD
Counters Roll Over at:
No Counters Reported
Configurable (attach explanation)
16 Bits
32 Bits
Other Value _____________
Point-by-point list attached
PROTOCOLO DNP
Configurable
Configurable
Configurable
Configurable
Configurable
Sometimes
Configurable
Configurable
Sometimes
Configurable
Configurable
Configurable
Configurable
Configurable
Configurable
Configurable
Configurable