Notes On Transport And Storage; Electrical Connection; Connection Examples - Resol SBS 2000 Traducción Del Manual Original

Estación de lavado y llenado
Ocultar thumbs Ver también para SBS 2000:
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

ATTENTION!
Pressure surge damage!
If the medium enters strongly heated, empty collectors, pressure
surges can occur.
Î Do not fi ll or fl ush the system during times of strong
irradiation!
ATTENTION!
Damage through overheating!
Fluid temperatures of more than 65 °C can lead to pump damage.
Î Make sure that the fl uid temperature does not exceed
65 °C.
ATTENTION!
Damage through dry run!
Dry run of the pump can lead to destruction of the pump.
Î Make sure the pump does not operate in dry run con-
dition!
ATTENTION!
Damage to the device through overheating!
During operation, the pump motor can reach a temperature of
up to 70 °C.
Î Make sure the air supply for motor cooling is not
blocked!
1.2

Notes on transport and storage

ATTENTION!
Damage through freezing!
Freezing can lead to damage of the fi lling and fl ushing station!
Î Make sure the station is stored in a frost-protected
place.
Î Make the pump does not contain any fl uid.
Note
Only transport the fi lling and fl ushing station in a horizontal position and
when it is empty.
2

Electrical connection

The cross-section of the connection cable must be at least 1.5 mm².
Note
For your own safety: only use the fi lling and fl ushing station in an electri-
cal circuit fused by a residual current device.
3

Connection examples

Flushing hose
Pressure
hose
Filling and fl ushing station
Filling and fl ushing unit
15

Publicidad

Tabla de contenido
loading

Tabla de contenido