Displaying The Internal Counters; Resetting The Internal Cycle Counters [Rct] - schmalz X-Pump SXP Instrucciones De Servicio

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

Schmalz X-Pump

Displaying the internal counters

 Press and hold <MENU> and <UP> for at least three seconds.
 Use the <UP> or <DOWN> key to select the desired counter.
 Press <ENTER> to confirm the selection.
The three low-order digits of the total counter value are displayed and the
rightmost LED (out2-h/c) lights.
The <UP> and <DOWN> keys can be used to display the other digits of the
counter value. The LEDs indicate which group of digits is being displayed, as
follows:
LED out2-h/c:
LED out2-H/C:
LED out1-h/c:
LED out1-H/C:
The total counter value consists of four groups of three digits each.
Example:
The current counter value is 48,618,593.

Resetting the internal cycle counters [rct]

 Press and hold <MENU> and <UP> for at least three seconds.
 Use the <UP> or <DOWN> key to select the menu item [rct].
 Press and hold the <ENTER> key for at least three seconds.
The display then blinks to indicate that all three counters have been reset to
zero.
If the <ENTER> is not held down for at least three seconds, the counters will
not be reset.
Exit from the counter function by pressing <MENU>.
4-26
Brief operating instructions
0
displaying 10
3
displaying 10
6
displaying 10
9
displaying 10
S
C H MA LZ

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

X-pump sxmp

Tabla de contenido