1. Specifications
1.1 Product identification
The battery-charger mod. CLN 0406 loads the batteries using a new technology which does not require either that
the batteries are flat or that a previous battery check has been carried out..
This way it is possible to recharge the batteries even if they are only partially loaded.
1.2 Tool composition
Pos.
Description
1
Power-supply cable and plug
2
Recharge cable and connector
3
LED 3 light
4
Charge fuse
5
Power-supply fuse
6
Sound alarm
1.3 Technical details
•
Model:
•
Recharge voltage:
•
Recharge current:
•
Network voltage:
•
Absorbed power:
•
Use temperature:
•
Storing temperature:
•
Index of protection:
2. Safety precautions
•
Before power-supplying the device , check that the details in the plate match with those of the electric network
(the plate is in the rear part of the device).
•
The device shall be used only for the aims it was designed for, that is to say for recharging the compatible
batteries. Any other use would be inadequate and dangerous.
•
Do not touch the device with wet hands or feet.
•
Do not use the device barefoot.
•
Do not leave the device outdoor..
•
Do not allow that children or untrained people use the device.
•
Before any cleaning or maintenance operations disconnect the device from the electric network.
•
In case of faults and/or wrong functioning, switch the device off and do not alter it. Any reparations shall be
carried out only by a CAMPAGNOLA S.r.l Authorised Service Point..
•
Make the device work at an environment temperature of 40 °C max.
•
Stop the device in case of strange noises or smells
•
Stop the device in case of battery-charger overheating
•
Do not open the battery-charger box for any reason.
•
The device is fitted with an earth connection and a CE homologation.
3. Recharging the battery
•
Controllare che il caricabatteria sia fra i modelli indicati nel manuale di utilizzo del gruppo di alimentazione che si
intende caricare.
Function
Supply power to the battery-charger
Allow the connection to the battery
Shows that the battery-charger is power-supplied
Protects the charging circuit
Protects the battery-charger from voltage modifications
Indicates a fault in the charging circuit
CLN 0406
14.8 V
6 A
90-264 VAC
130 W
+10 °C / +40 °C
-10 °C / +45 °C
IP 20
10
Photo
A
A
A
A
B
Not visible