LEVELLING
To carry out this operation, proceed as follows.
1 - Unscrew the nut (A).
2 - Adjust the feet (B) to level the appliance.
3 - Tighten the nut (A).
ELECTRICAL CONNECTION
Important
The connection must be made by authori-
sed, skilled personnel, in accordance with
the relevant legal requirements, using
appropriate and specified materials.
The appliance is supplied with opera-
ting voltage 400V/3N.
Caution - warning
Before doing any work, cut off the mains
electricity supply.
Connect the appliance to the mains electricity sup-
IT
ply as follows.
1 - If not already present, install a circuit-breaker
(A) with overload cutout and differential safety
GB
breaker close to the appliance.
DE
FR
ES
A
English
F
2 - Undo the screws (B) of the terminal board sup-
port (C).
3 - Connect the circuit-breaker (A) to the terminal
board (D), passing the cable through the appli-
ance's cable gland (E) as shown in the diagram
and in the electrical system diagram at the back
of the manual.
Use a flexible cable with at least type H07RN-F
characteristics, rated for an operating tempera-
ture of at least 80°C.
– Power supply cable gauge ≥ 2,5 mmq.
Important
When connecting, take care to connect the
neutral and earth lines and the ground ter-
minal line (F).
4 - Tighten the cable gland (G).
5 - Replace the terminal board support (C) on com-
pletion of the operation.
G
C
B
- 16 -
A
B
E
D