UK
Fault
The appliance
Too much ice on the evaporator
turns on, but the
Condenser blocked with dust
temperature is too
Doors are not shut properly
high/low
Appliance is located near a heat
source or air flow to the condenser
is being interrupted
Ambient temperature is too high
Unsuitable foodstuffs are being
stored in the appliance
Appliance is overloaded
The appliance is
The appliance is not properly
leaking water
levelled
The discharge outlet is blocked
Movement of water to the drain is
obstructed
The water container is damaged
The drip tray is overflowing
The appliance is
Loose nut/screw
unusually loud
The appliance has not been installed
in a level or stable position
Technical Specifications
Model
Voltage
Power
FA854
230V 50Hz
110W
FA855
230V 50Hz
110W
FA856
230V 50Hz
122W
FA857
230V 50Hz
122W
DA680
230V 50Hz
110W
6
FA854_FA855_ FA856_FA857_DA680 _ML_A5_v1_20190708.indb 6
Probable Cause
Temperature
Current
Capacity
Range
0.8A
2°C - 8°C
5 x gastronorm 1/4
Container
0.8A
2°C - 8°C
7 x gastronorm 1/4
Container
0.8A
2°C - 8°C
8 x gastronorm 1/4
Container
0.8A
2°C - 8°C
10 x gastronorm 1/4
Container
0.8A
2°C - 8°C
6 x gastronorm 1/4
Container
Solution
Defrost the appliance
Clean the Condenser
Check doors are shut and seals are not
damaged
Move the appliance to a more suitable
location
Increase ventilation or move appliance to a
cooler position
Remove any excessive hot foodstuffs or
blockages to the fan
Reduce the amount of food stored in the
appliance
Adjust the screw feet to level the appliance
(if applicable)
Clear the discharge outlet
Clear the floor of the appliance (if
applicable)
Call POLAR agent or qualified Technician
Empty the drip tray (if applicable)
Check and tighten all nuts and screws
Check installation position and change if
necessary
Dimensions
Refrigerant
H x W x D mm
R600a 45g
274 x 1200 x 335
R600a 45g
274 x 1500 x 335
R600a 45g
274 x 1800 x 335
R600a 45g
274 x 2000 x 335
R600a 45g
274 x 1400 x 335
Weight
(kg)
25
29
32
34
27
2019/7/8 11:58