Taking The Equipment Off; Maintenance Schedule; Spare Parts; Parts List - Sundstrom SR 500 Instrucciones De Uso

Ocultar thumbs Ver también para SR 500:
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 40

3.9 Taking the equipment off

Leave the polluted area before taking the equipment off.
• Take off the head top.
• Switch off the fan unit.
• Release the belt and remove the fan unit.
After use, the equipment must be cleaned and inspected.
See 4 Maintenance.
4. Maintenance
The person who is responsible for cleaning and mainte-
nance of the equipment must have suitable training and
be well acquainted with work of this type.
4.1 Cleaning
Sundström cleaning tissue SR 5226 are recommended
for daily care. At more thorough cleaning or decontami-
nation - proceed as follows:
• Assemble the plug kit. See 3.5 e.
• Use a soft brush or sponge moistened with a solution
of water and dishwashing detergent or the like.
• Rinse the equipment and leave it to dry.
N.B. Never use a solvent for cleaning.
4.2 Storage
After cleaning, store the equipment in a dry and clean
place at room temperature. Avoid exposing it to direct
sunlight. The flow meter can be turned inside out and
can be used as a storage bag for the head top.

4.3 Maintenance schedule

The following schedule shows the recommended mini-
mum maintenance procedures required in order to en-
sure that the equipment is always in functional
condition.
Before
Visual inspection
Performance check
Cleaning
Change of fan gaskets

4.4 Spare parts

Always use genuine Sundström parts. Do not modify the
equipment. The use of non-genuine parts or modifica-
tion of the equipment may reduce the protective function
and put at risk the approvals received by the product.
4.4.1 To change the particle filters/
gas filters/combined filters
Change the particle filters at the latest when they are
clogged. The fan senses when this has occurred and
provides a warning as described in 3.6 under the
heading Operation/performance. The gas filters should
preferably be changed in accordance with a predetermi-
ned schedule. If no measurements are made on site, the
gas filters should be changed once a week or more fre-
quently if the pollutants can be smelt or tasted in the
head top.
Bear in mind that both filters/combined filters must be
changed at the same time and must be of the same type
and class. Proceed as follows:
• Switch off the fan unit.
• Unscrew the filter/combined filter.
38
After
use
use
• Release the pre-filter holder. Fig. 37.
• Change the pre-filter in its holder. Clean as
necessary.
• To release the particle filter SR 510 from the
adapter, proceed as follows:
o Grip the filter with one hand.
o Place the thumb of the other hand on the under-
side of the adapter at the semicircular gap.
Fig. 38.
o Then prise out the filter. Fig. 39.
• To release the particle filter SR 510 from the gas
filter, proceed as follows:
o Grip the gas filter with one hand.
o Insert a coin or some other flat object, e.g. the fil-
ter adapter, in the joint between the particle and
gas filters.
o Then prise out the filter. Fig. 40.
• Fit new filters/combined filters. See 3.5 d.
4.4.2 To change the gaskets
The gaskets in the filter mountings of the fan unit prevent
polluted air being drawn into the fan unit. They must be
changed once a year or more frequently if wear or age-
ing is detected. Proceed as follows:
• Switch off the fan unit.
• Screw out the filters.
• The gasket has a groove all round and is fitted on a
flange below the threads in the filter mounting. Fig. 41.
• Remove the old gasket.
• Fit the new gasket onto the flange. Check that the
gasket is in place all round.

5. Parts list

Fig. 2.
Annually
Item Part
No.
1. Hood SR 561
2. Hood SR 562
3. Hood SR 520 M/L
3. Hood SR 520 S/M
4. Hood SR 530
5. Face shield SR 540
6. Face shield SR 570
7. Full face mask SR 200, PC visor
7. Full face mask SR 200, glass visor
8. Half mask SR 900 S
8. Half mask SR 900 M
8. Half mask SR 900 L
9. Welding shield SR 590
10. Welding shield SR 592
12. Helmet with visor SR 580
13. Welding shield/Helmet with visor
SR 584/SR 580
14. Hose SR 550
14. Hose SR 551
15. Hose SR 951
16. Twin hose SR 952
17. Gold-plated shield SR 587
18. Shield 2/3, EN 3 SR 588-1
18. Shield 2/3, EN 5 SR 588-2
19. Flow meter SR 356
20. Steel net disc SR 336
21. Asbestos kit SR 509
22. Storage bag SR 505
23. STD Standard battery, 2.2 Ah
Ordering No.
H06-5012
H06-5112
H06-0212
H06-0312
H06-0412
H06-0512
H06-6512
H01-1212
H01-1312
H01-3012
H01-3112
H01-3212
H06-4012
H06-4412
H06-8012
H06-8310
T01-1216
T01-1218
T01-3003
R01-3009
R06-0824
R06-0825
R06-0826
R03-0346
T01-2001
T06-0105
T06-0102
R06-0108

Publicidad

Tabla de contenido
loading

Tabla de contenido