M03 - PASSWORD
P03.01
Enable passwords
P03.02
User level password
P03.03
Advanced level password
M04 - INTEGRATION
P04.01
Integration mode
P04.02
Power integration time
P04.03
Current integration time
P04.04
Voltage integration time
P04.05
Frequency integration time
M05 - HOUR METER
P05.01
Hour counters (meters) enable
P05.02
Partial hour counter (meter) enable
P05.03
Channel number (x)
M06 - TREND GRAPH
P06.01
Measurement for trend graph
P06.02
Scale autorange
P06.03
Full scale value
P06.04
Full scale multiplier
10
P03.01 = If set to OFF, password management is disabled and the access to setup parameters and commands menu is allowed.
P03.02 = When P03.01 is enabled, value to be specified to get user access.
P03.03 = Like P03.02, but referred to advanced access.
P04.01 = Selection of average reading calculation method:
Fixed - Readings are integrated for the set time. Every time the integration time elapses, the Average value is updated with the result of the last
integration.
Shift - The instantaneous values are integrated for a period f time equal to 1/15th of the set time. Every time this interval elapses, the oldest value is
replaced with the new one just calculated. The average value is updated every 1/15th of the time set, considering a time-sliding window that groups the
last 15 calculated values, with a total length equal to integration time setting.
Sync - Like fixed mode, but the integration intervals are started by an external digital input programmed with Synchronisation function.
Bus - Like fixed mode, but the integration intervals are started by communication messages on the serial bus.
P04.02 = Average readings integration time, used for active, reactive and apparent power.
P04.03, P04.04, P04.05 = Readings integration time (AVG) for the correspondent measurements.
P05.01 = If set to OFF, the hour counters are disabled and the hour meter page is not shown.
P05.02 = If set to OFF, the partial hour counter is not incremented. If ON, it is incremented as long as the DME is powered. If set to one of the internal variables
(LIMn-INPx), it is incremented only when the condition is valid.
P05.03 = Number of the channel (x) of the variable eventually used in the previous parameter. Example: If the partial hour counter must count the time during
which one measurement is above a certain threshold, defined by LIM3, then program LIMx in the previous parameter and channel 3 in this parameter.
P06.01 = Selects the reading to be shown on the trend graph page.
P06.02 = Choice for the vertical scale, between automatic (ON) adjustment per readings or fixed (OFF) range defined by the user.
P06.03 = Full scale range value. The unit of measure is the one defined by the selected reading.
P06.04 = Full scale value multiplier.
UdM
Default
Range
OFF
OFF-ON
1000
0-9999
2000
0-9999
UdM
Default
Range
Scorr.
Scorrevole
Sincronismo
min
15
1-60min
min
15
1-60min
min
1
1-60min
min
1
1-60min
UdM
Default
Range
ON
OFF-ON
ON
OFF-ON- INPx-
1
UdM
Default
Range
kW (tot) AVG
VL-L (eq) AVG
kW (tot) AVG
kvar (tot) AVG
kVA (tot) AVG
ON
OFF-ON
1000
0-1000
x1
x1 – x1k – x1M
G
B
Fisso
Bus
Fixed
Shift
Sync
Bus
LIMx
1-4